Por trabajos de mejora del repositorio, la plataforma estará en mantenimiento entre las 15:30 y las 15:45. No se deben realizar envíos durante esa franja.

Hysteresis correction of tactile sensor response with a generalized Prandtl–Ishlinskii model

dc.centroEscuela de Ingenierías Industrialeses_ES
dc.contributor.authorSánchez-Durán, José Antonio
dc.contributor.authorOballe-Peinado, Óscar
dc.contributor.authorCastellanos-Ramos, Julián
dc.contributor.authorVidal-Verdú, Fernando
dc.date.accessioned2024-09-20T06:55:40Z
dc.date.available2024-09-20T06:55:40Z
dc.date.issued2012
dc.departamentoElectrónica
dc.description.abstractTactile sensors are basically arrays of force sensors. Most of these force sensors are made of polymers or conductive rubber to lower cost, especially in the case of large area low-medium resolution tactile sensors. The consequence of such a decrease in cost and complexity is a worsening in performance. Hysteresis and drift are two main sources of error. Other tactile sensors do not present such limitations per se, however they are covered by a protective elastic layer in their final location and this covering can also lead to limitations. This paper presents a method to reduce the error caused by hysteresis in tactile sensors. This method is based on the generalized Prandtl-Ishlinskii model that has been applied to characterize hysteresis and saturation nonlinearities in smart actuators. The approximation error depends on several parameters as well as on the envelope functions that are chosen. Different alternatives are explored in the paper. Moreover, the model can also be inverted. This inverse model allows the force values to be obtained from the tactile sensor output while reducing the errors caused by hysteresis. In this paper the results of such an inversion are compared with other alternatives to register the data that do not compensate hysteresis. The average value of the hysteresis error measured in the experimental curve is 7.20% for an input range of 206kPa, while this error is 1.51% following the compensation procedure. Since the implementation of tactile sensors usually results in the electronics being close to the raw sensor, and this hardware is also commonly based on a microcontroller or even on a FPGA, it is possible to add the algorithms presented in this paper to the set of compensation and calibration procedures to run in the smart sensor.es_ES
dc.description.sponsorshipUniversidad de Málaga. Spanish government under contract TEC2009-14446- C02.es_ES
dc.identifier.citationSánchez-Durán, J.A., Oballe-Peinado, Ó., Castellanos-Ramos, J. et al. Hysteresis correction of tactile sensor response with a generalized Prandtl–Ishlinskii model. Microsyst Technol 18, 1127–1138 (2012). https://doi.org/10.1007/s00542-012-1455-7es_ES
dc.identifier.doi10.1007/s00542-012-1455-7
dc.identifier.urihttps://hdl.handle.net/10630/32687
dc.language.isoenges_ES
dc.publisherSpringer-Verlages_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectTactoes_ES
dc.subjectDetectoreses_ES
dc.subject.otherHysteresis correctiones_ES
dc.subject.otherTactile sensorses_ES
dc.titleHysteresis correction of tactile sensor response with a generalized Prandtl–Ishlinskii modeles_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication26b8b990-9fa9-4f37-a1ab-d63c3619bb88
relation.isAuthorOfPublicationf46c97dc-f428-4b49-9d98-eaaf5ae974e2
relation.isAuthorOfPublication4d5646a9-1513-4a47-86e7-1c7d494066d8
relation.isAuthorOfPublication.latestForDiscovery26b8b990-9fa9-4f37-a1ab-d63c3619bb88

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
20120316-Publicacion_MicrosystemTechnologies.pdf
Size:
1.47 MB
Format:
Adobe Portable Document Format
Description:
Artículo principal
Download

Description: Artículo principal

Collections