On the Advantages of Symmetrical Over Asymmetrical Multiphase AC Drives With Even Phase Number Using Direct Controllers.

dc.centroEscuela de Ingenierías Industrialeses_ES
dc.contributor.authorGonzález Prieto, Ángel
dc.contributor.authorGonzález Prieto, Ángel
dc.contributor.authorGómez Yepes, Alejandro
dc.contributor.authorDurán-Martínez, Mario Javier
dc.contributor.authorDoval Gandoy, Jesús
dc.date.accessioned2025-01-29T12:53:26Z
dc.date.available2025-01-29T12:53:26Z
dc.date.issued2021-08-23
dc.departamentoIngeniería Eléctrica
dc.description.abstractMultiphase electric drives offer attractive advantages over conventional three-phase systems. Some of the benefits are shared by all multiphase configurations, but the performance can be highly affected by the specific location of the stator windings. While the asymmetrical configuration has been traditionally a popular choice, the symmetrical disposition in even-phase machines has a main advantage: it is possible to generate α–β voltages without any contribution in different x–y subspaces. This article explains and demonstrates this feature for the general case of distributed-winding symmetrical n-phase machines, with n being an even number. Fortunately, direct controllers can benefit from this characteristic by exclusively selecting voltage states with only α–β voltage production. To illustrate this capability, a finite-control-set model predictive control (FCS-MPC) using these special voltage states is also suggested in this work for symmetrical six-phase electric drives. This approach provides a greater simplicity and much less current distortion than in standard FCS-MPC for the asymmetrical configuration. Comparative experimental results confirm the minimal x–y injection of symmetrical configurations thanks to the proposed control actions (i.e., voltage states).es_ES
dc.identifier.citationA. González-Prieto, I. González-Prieto, A. G. Yepes, M. J. Duran and J. Doval-Gandoy, "On the Advantages of Symmetrical Over Asymmetrical Multiphase AC Drives With Even Phase Number Using Direct Controllers," in IEEE Transactions on Industrial Electronics, vol. 69, no. 8, pp. 7639-7650, Aug. 2022, doi: 10.1109/TIE.2021.3104588.es_ES
dc.identifier.doi10.1109/TIE.2021.3104588
dc.identifier.urihttps://hdl.handle.net/10630/37303
dc.language.isoenges_ES
dc.publisherIEEE Xplorees_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectIngeniería eléctricaes_ES
dc.subject.otherDirect controllerses_ES
dc.subject.otherHarmonic distortiones_ES
dc.subject.otherModel predictive control (MPC)es_ES
dc.subject.otherMultiphase electric driveses_ES
dc.subject.otherStator winding arrangementes_ES
dc.titleOn the Advantages of Symmetrical Over Asymmetrical Multiphase AC Drives With Even Phase Number Using Direct Controllers.es_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationb42a9855-ccb7-4c44-b2c5-10bc75ca7bd0
relation.isAuthorOfPublication.latestForDiscoveryb42a9855-ccb7-4c44-b2c5-10bc75ca7bd0

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
ALL_21-TIE-0428.pdf
Size:
3.49 MB
Format:
Adobe Portable Document Format
Description:
Versión aceptada del manuscrito.
Download

Description: Versión aceptada del manuscrito.

Collections