Kinematic parameters related to functional capacity, fatigue, and breathlessness during the 6-min walk test in older adults with heart failure with preserved ejection fraction

dc.contributor.authorFuentes-Abolafio, Iván José
dc.contributor.authorTrinidad-Fernández, Manuel
dc.contributor.authorRicci, Michele
dc.contributor.authorRoldán-Jiménez, Cristina
dc.contributor.authorGómez-Huelgas, Ricardo
dc.contributor.authorArjona-Caballero, José María
dc.contributor.authorEscriche-Escuder, Adrián
dc.contributor.authorBernal-López, María Rosa
dc.contributor.authorPérez-Belmonte, Luis Miguel
dc.contributor.authorCuesta-Vargas, Antonio
dc.date.accessioned2025-01-13T08:27:21Z
dc.date.available2025-01-13T08:27:21Z
dc.date.issued2024-01-12
dc.departamentoFisioterapia
dc.description.abstractAims: This paper aims to assess kinematic parameters related to functional capacity, fatigue, and breathlessness during the 6-min walk test (6MWT) in patients with heart failure with preserved ejection fraction (HFpEF). Methods and results: A cross-sectional study was conducted in which adults 70 years or older with HFpEF were voluntarily recruited between April 2019 and March 2020. An inertial sensor was placed at the L3-L4 level and another on the sternum to assess kinematic parameters. The 6MWT was divided into two 3-min phases. Leg fatigue and breathlessness, assessed by the Borg scale, the heart rate (HR), and the oxygen saturation (SpO2), were measured at the beginning and the end of the 6MWT. The difference in kinematic parameters between the 6MWT two 3-min phases was also calculated. Bivariate Pearson correlations and subsequent multivariate linear regression analysis were performed. Seventy older adults with HFpEF (mean = 80.74 years old) were included. Kinematic parameters explained 81.00% of the functional capacity, 45.50% of the leg fatigue and 66.10% of the breathlessness variance. Moreover, kinematic parameters could explain 30.90% of the SpO2 variance at the end of the 6MWT. Kinematic parameters also explained 33.10% of the SpO2 difference between the beginning and end of 6MWT. Kinematic parameters explained neither the HR variance at the end of 6MWT nor the HR difference between the beginning and end. Conclusion: Gait kinematics from L3-L4 and sternum explain a part of the variance in subjective outcomes, assessed by the Borg scale, and objective outcomes such as functional capacity and SpO2. The kinematic assessment allows clinicians to quantify fatigue and breathlessness through objective parameters related to the patient's functional capacity.es_ES
dc.identifier.citationFuentes-Abolafio IJ, Trinidad-Fernández M, Ricci M, Roldán-Jiménez C, Gómez-Huelgas R, Arjona-Caballero JM, Escriche-Escuder A, Bernal-López MR, Pérez-Belmonte LM, Cuesta-Vargas AI. Kinematic parameters related to functional capacity, fatigue, and breathlessness during the 6-min walk test in older adults with heart failure with preserved ejection fraction. Eur J Cardiovasc Nurs. 2024 Jan 12;23(1):69-80. doi: 10.1093/eurjcn/zvad027. PMID: 36808232.es_ES
dc.identifier.doihttps://doi.org/10.1093/eurjcn/zvad027
dc.identifier.urihttps://hdl.handle.net/10630/36158
dc.language.isoenges_ES
dc.publisherEur J Cardiovasc Nurses_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectEjercicio físico - Aspectos fisiológicoses_ES
dc.subject.other6-min walk testes_ES
dc.subject.otherBreathlessnesses_ES
dc.subject.otherFatiguees_ES
dc.subject.otherHeart failurees_ES
dc.subject.otherInertial sensores_ES
dc.subject.otherKinematicses_ES
dc.titleKinematic parameters related to functional capacity, fatigue, and breathlessness during the 6-min walk test in older adults with heart failure with preserved ejection fractiones_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationae123d5b-4c17-4d63-9708-e83f8477984a
relation.isAuthorOfPublication440789d1-2ac6-48bb-b79f-adce381a4c42
relation.isAuthorOfPublication2f9b4b12-85ef-4742-8324-eafc98ed6805
relation.isAuthorOfPublication94126d4b-371d-4727-a252-f4182972d4b6
relation.isAuthorOfPublication.latestForDiscoveryae123d5b-4c17-4d63-9708-e83f8477984a

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Cinemática y fatiga en 6MWT en HFpEF.pdf
Size:
657.62 KB
Format:
Adobe Portable Document Format
Description:

Collections