Optical Camera-Based Multiplexed Photonic Sensor System With Ultralow Detection Limit for Biomedical Applications

dc.centroE.T.S.I. Telecomunicaciónes_ES
dc.contributor.authorPérez-Sánchez, Laura
dc.contributor.authorSánchez-Ramírez, Ana
dc.contributor.authorLeuermann, Jonas
dc.contributor.authorMolina-Fernández, Íñigo
dc.date.accessioned2025-10-07T09:32:49Z
dc.date.available2025-10-07T09:32:49Z
dc.date.created2025-10
dc.date.issued2025-10-01
dc.departamentoInstituto de Tecnología e Ingeniería del Software de la Universidad de Málagaes_ES
dc.description.abstractPhotonic sensors based on Mach–Zehnder interferometric architectures with phase-coherent readout have demonstrated their potential for the integration into medical diagnostic devices. Their compact design, low cost, and ability to detect multiple biomarkers make them potentially applicable for the point-of-care. Achieving both high throughput and optimal sensor performance requires a miniaturized interrogation system with multiplexed readout capability that facilitates alignment and at the same time offers a high signal-to-noise ratio (SNR). In this work, the use of an optical camera (OC)-based system suited for multiplexed integrated photonic sensor detection is investigated. Its system level model is derived to determine the SNR and its associated limit of detection (LOD). This model allows achieving optimal sensing performance by tuning the photonic chip, the optical system, and the camera detection parameters. In agreement with model expectations, experimental results show that this system allows reaching for bulk detection limits of ∼10−7 refractive index units (RIUs) for a system comprising three sensors, representing a state-of-the-art achievement.es_ES
dc.description.sponsorship10.13039/100014440-Ministerio de Ciencia e Innovación y Universidades and the Agencia Estatal de Investigación, Spain (Grant Number: DIN2022-012816, PRE2020-096438 and TED2021-130400B-I00)es_ES
dc.description.sponsorshipMinisterio para la Transformación Digital y de la Función Pública, Spain (Plan de Recuperación, Transformación y Resiliencia, NextGenerationEU., MICROELECTRONICS) (Grant Number: TSI-069100-2023-0013)es_ES
dc.description.sponsorshipUniversidad de Málagaes_ES
dc.identifier.citationL. Pérez-Sánchez, A. Sánchez-Ramírez, J. Leuermann and I. Molina-Fernández, "Optical Camera-Based Multiplexed Photonic Sensor System With Ultralow Detection Limit for Biomedical Applications," in IEEE Transactions on Instrumentation and Measurement, vol. 74, pp. 1-11, 2025, Art no. 9536111, doi: 10.1109/TIM.2025.3612559.es_ES
dc.identifier.doi10.1109/TIM.2025.3612559
dc.identifier.urihttps://hdl.handle.net/10630/40110
dc.language.isoenges_ES
dc.publisherIEEEes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectFotónicaes_ES
dc.subjectInterferómetroses_ES
dc.subjectSensoreses_ES
dc.subjectSeñales, Teoría de (Telecomunicación)es_ES
dc.subjectBiomedicina - Investigaciónes_ES
dc.subject.otherLimit of detection (LOD)es_ES
dc.subject.otherMach–Zehnder interferometer (MZI)es_ES
dc.subject.otherMultiplexed sensores_ES
dc.subject.otherOptical camera (OC)es_ES
dc.subject.otherSignal-to-noise ratio (SNR)es_ES
dc.titleOptical Camera-Based Multiplexed Photonic Sensor System With Ultralow Detection Limit for Biomedical Applicationses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationf8516b4a-9f57-4d55-b3ff-3b4d35460a81
relation.isAuthorOfPublication.latestForDiscoveryf8516b4a-9f57-4d55-b3ff-3b4d35460a81

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Optical_Camera-Based_Multiplexed_Photonic_Sensor_System_With_Ultralow_Detection_Limit_for_Biomedical_Applications.pdf
Size:
2.41 MB
Format:
Adobe Portable Document Format
Description:

Collections