A source model for the electron contamination of clinical linac heads in photon mode.

dc.centroFacultad de Cienciases_ES
dc.contributor.authorGonzález-Infantes, Wilfredo
dc.contributor.authorAnguiano, Marta
dc.contributor.authorLallena, Antonio
dc.date.accessioned2025-01-28T08:15:45Z
dc.date.available2025-01-28T08:15:45Z
dc.date.issued2015-07-30
dc.departamentoFísica Aplicada I
dc.descriptionhttps://publishingsupport.iopscience.iop.org/questions/what-is-iop-publishings-green-open-access-policy/es_ES
dc.description.abstractIn this work a general source model has been developed to describe the electron contamination in clinical linac heads when operating in photon mode. The model includes two-sources that take into account the electrons generated in the linac head and in the air gap between the linac head and the patient. Their geometrical characteristics are determined by fitting the model of total fluence distribution to a set of fluence data in air just before entering the water phantom and for various field sizes up to 40 × 40 cm2 . The electron energy distributions are fitted to those obtained from phase-space files calculated with PENELOPE at the patient surface and for the largest field size. To verify the model, percentage depth doses and transverse profiles in water obtained from a Monte Carlo simulation performed with a complete and detailed linac geometry are compared to those found with the source model. Six linacs (three operating at 6 MV, one at 15 MV and two at 18 MV) have been studied. A comparison with the results obtained with a single source model is also carried out. The two-source model proposed provides a reasonably good description of the dose absorbed in water for all irradiation fields considered. The largest differences occur at the entrance of the phantom, for the low energy configurations and the smaller fields, reaching ∼ 15% at most. The two-source model describes much better than the single source one the lateral profiles in depth.es_ES
dc.identifier.citationW González et al 2015 Biomed. Phys. Eng. Express 1 025202es_ES
dc.identifier.doi10.1088/2057-1976/1/2/025202
dc.identifier.urihttps://hdl.handle.net/10630/37131
dc.language.isoenges_ES
dc.publisherIOPes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectAceleradores linealeses_ES
dc.subjectElectroneses_ES
dc.subject.otherElectron source modeles_ES
dc.subject.otherLINACes_ES
dc.titleA source model for the electron contamination of clinical linac heads in photon mode.es_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication6bb188ce-1d12-4894-a2ce-6b247cdc3d64
relation.isAuthorOfPublication.latestForDiscovery6bb188ce-1d12-4894-a2ce-6b247cdc3d64

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
vsmee-20.pdf
Size:
662.25 KB
Format:
Adobe Portable Document Format
Description:

Collections