Monitoring changes of the tibialis anterior during dorsiflexion with electromyography, sonomyography, dynamometry and kinematic signals
| dc.centro | Facultad de Ciencias de la Salud | es_ES |
| dc.contributor.author | Ruiz-Muñoz, María | |
| dc.contributor.author | Martín-Martín, Jaime | |
| dc.contributor.author | González-Sánchez, Manuel | |
| dc.contributor.author | Cuesta-Vargas, Antonio | |
| dc.date.accessioned | 2014-01-20T12:59:57Z | |
| dc.date.available | 2014-01-20T12:59:57Z | |
| dc.date.issued | 2014-01-20 | |
| dc.departamento | Fisioterapia | |
| dc.description.abstract | Dorsiflexion (DF) of the foot plays an essential role in both controlling balance and human gait. Electromyography and Sonomyography can provide information on several aspects of muscle function. The aim was to describe a new method for real-time monitoring of muscular activity, as measured using EMG, muscular architecture, as measured using SMG, force, as measured using dynamometry, and kinematic parameters, as measured using IS during isometric and isotonic contractions of the foot DF. The present methodology may be clinically relevant because it involves a reproducible procedure which allows the function and structure of the foot DF to be monitored. | es_ES |
| dc.description.sponsorship | Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech. Seville; Spain; 25 September 2013 through 28 September 2013; Code 101721 | es_ES |
| dc.identifier.uri | http://hdl.handle.net/10630/6900 | |
| dc.language.iso | eng | es_ES |
| dc.relation.eventdate | 25 September 2013 through 28 September 2013 | es_ES |
| dc.relation.eventplace | Sevilla | es_ES |
| dc.relation.eventtitle | 13th Mediterranean Conference on Medical and Biological Engineering and Computing 2013, MEDICON 2013; Seville; Spain; 25 September 2013 through 28 September 2013; Code 101721 | es_ES |
| dc.rights.accessRights | open access | |
| dc.subject | Informática médica | es_ES |
| dc.subject.other | Dorsal flexion | es_ES |
| dc.subject.other | Dynamometry | es_ES |
| dc.subject.other | Electromyography | es_ES |
| dc.subject.other | Kinematic | es_ES |
| dc.subject.other | Sonomyography | es_ES |
| dc.subject.other | Tibialis anterior | es_ES |
| dc.title | Monitoring changes of the tibialis anterior during dorsiflexion with electromyography, sonomyography, dynamometry and kinematic signals | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | SMUR | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 17f274b8-6474-410f-8a9c-02711212c6e3 | |
| relation.isAuthorOfPublication | af904741-d538-4bf8-a882-d00782271171 | |
| relation.isAuthorOfPublication | d1d67599-b8c6-4fc4-834d-eeeae4eef078 | |
| relation.isAuthorOfPublication | 94126d4b-371d-4727-a252-f4182972d4b6 | |
| relation.isAuthorOfPublication.latestForDiscovery | 17f274b8-6474-410f-8a9c-02711212c6e3 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- María Ruiz Muñoz - Medicon 1-2.pdf
- Size:
- 116.57 KB
- Format:
- Adobe Portable Document Format
- Description: