Longitudinal validity of abdominal adiposity assessment by regional bioelectrical impedance
| dc.centro | Facultad de Medicina | es_ES |
| dc.contributor.author | Alvero-Cruz, José Ramón | |
| dc.contributor.author | García-Romero, Jerónimo | |
| dc.contributor.author | Carrillo-de-Albornoz, Margarita | |
| dc.contributor.author | Jimenez Lopez, Manuel | |
| dc.contributor.author | Correas-Gómez, Lorena | |
| dc.contributor.author | Peñaloza, Piero | |
| dc.contributor.author | López-Fernández, Iván | |
| dc.contributor.author | Álvarez-Carnero, Elvis | |
| dc.date.accessioned | 2024-02-02T11:43:26Z | |
| dc.date.available | 2024-02-02T11:43:26Z | |
| dc.date.issued | 2018-07-01 | |
| dc.departamento | Fisiología Humana, Histología Humana, Anatomía Patológica y Educación Físico Deportiva | |
| dc.description.abstract | The main goal of this study was to analyze the longitudinal agreement between changes in trunk and abdominal adiposity variables assessed by DXA and portable bioimpedance device (ViScan). A total of 44 women, enrolled in a 4-month exercise intervention, were included in this analysis. Trunk/abdominal compartments were assessed by ViScan and DXA. Adjusted correlations for age and FM at first assessment (pre) were utilized to perform concurrent validation among methods and completed with an agreement analysis. We observed significant differences between the changes detected by DXA and ViScan for %TFM (difference = -1.41%; p < 0.05), and proportional bias (Kendall's Tau = 0.53; p < 0.0001). Changes in abdominal adiposity were similar (difference = -0.1037 z-score units, p = 0.53), although there was proportional bias (Kendall's Tau = -0.24, p < 0.022). ViScan has a limited capability to evaluated changes in trunk and abdominal adiposity, at least for clinical purposes in adult women. © 2018 Macmillan Publishers Limited, part of Springer Nature. | es_ES |
| dc.description.sponsorship | No hubo financiación externa | es_ES |
| dc.identifier.doi | 10.1038/s41430-018-0129-7 | |
| dc.identifier.uri | https://hdl.handle.net/10630/29715 | |
| dc.language.iso | eng | es_ES |
| dc.publisher | Springer Nature | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.subject | Obesidad | es_ES |
| dc.subject | Abdomen - Medición | es_ES |
| dc.subject.other | Abdomen | es_ES |
| dc.subject.other | Absorptiometry | es_ES |
| dc.subject.other | Photon | es_ES |
| dc.subject.other | Adiposity | es_ES |
| dc.subject.other | Adult | es_ES |
| dc.subject.other | Anthropometry | es_ES |
| dc.subject.other | Body Composition | es_ES |
| dc.subject.other | Electric Impedance | es_ES |
| dc.subject.other | Female | es_ES |
| dc.subject.other | Humans | es_ES |
| dc.subject.other | Intra-Abdominal Fat | es_ES |
| dc.subject.other | Longitudinal Studies | es_ES |
| dc.subject.other | Middle Aged | es_ES |
| dc.subject.other | Obesity | es_ES |
| dc.subject.other | Abdominal | es_ES |
| dc.subject.other | Reproducibility of Results | es_ES |
| dc.subject.other | Torso | es_ES |
| dc.title | Longitudinal validity of abdominal adiposity assessment by regional bioelectrical impedance | es_ES |
| dc.type | journal article | es_ES |
| dc.type.hasVersion | AM | es_ES |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 04961ec1-eb3a-4e93-b096-d7fa419187ad | |
| relation.isAuthorOfPublication | 9b679eb6-3b1b-40c1-87e2-3f495c228add | |
| relation.isAuthorOfPublication | 1696c674-14f2-4d6b-bcc8-75b005929eb8 | |
| relation.isAuthorOfPublication | 10a65ad4-1ab9-4ab2-8019-f29e41f79a28 | |
| relation.isAuthorOfPublication | 4c0c4394-7c47-4621-b6bb-436891c2a398 | |
| relation.isAuthorOfPublication.latestForDiscovery | 04961ec1-eb3a-4e93-b096-d7fa419187ad |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- 2018 EJCN Longitudinal validity of abdominal adiposity assessment by regional.pdf
- Size:
- 368.92 KB
- Format:
- Adobe Portable Document Format
- Description:
- Artículo principal
Description: Artículo principal