Use of Semi-Indirect Evaporative Cooling in HVAC systems: experimental study

dc.centroEscuela de Ingenierías Industrialeses_ES
dc.contributor.authorSocci, Luca
dc.contributor.authorRey-Hernández, Javier M.
dc.contributor.authorRocchetti, Andrea
dc.contributor.authorDomínguez-Muñoz, Fernando
dc.contributor.authorRey-Hernández, Alberto
dc.contributor.authorRey-Martínez, Francisco J.
dc.date.accessioned2025-07-29T10:49:14Z
dc.date.available2025-07-29T10:49:14Z
dc.date.issued2024-07-08
dc.departamentoIngeniería Mecánica, Térmica y de Fluidoses_ES
dc.description.abstractThis study investigates the application of a Semi-Indirect Evaporative Cooler (SIEC) to develop a Decarbonised Evaporative-Based Air Conditioning System (DEBACS). The research aims to show the benefit of using the SIEC in combination with a traditional Air Conditioning Unit to enhance the energy efficiency of an HVAC system. The SIEC, constructed from ceramic material, operates in both dry and wet modes. By spraying water on the inner side, it functions as an efficient air-to-air recuperator, with the ceramic material improving water distribution and device performance. The SIEC device has been experimentally tested. Tests were conducted in both dry and wet modes across three airflow rates and three temperature levels. Moreover, a simple model that describes the SIEC behaviour in general operative conditions has been derived. Results indicated that under optimal conditions (lowest supply airflow), the SIEC achieved an efficiency ratio between 50 % and 70 % in dry mode, and nearly 100 % in wet mode, with the wet mode improving efficiency ratio by 30–50 %. These findings underscore the potential of the ceramic SIEC device as an effective technology for air conditioning systems, promoting energy efficiency, compliance with EPBD standards, and significant decarbonisation in the HVAC sector.es_ES
dc.identifier.citationJournal of Building Engineering 95 (2024) 110158es_ES
dc.identifier.doi10.1016/j.jobe.2024.110158
dc.identifier.urihttps://hdl.handle.net/10630/39566
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.relation.projectIDOESTE Project (University of Valladolid)es_ES
dc.relation.projectIDLime4Health (Technical University of Madrid - UPM)es_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectAire acondicionadoes_ES
dc.subjectIngeniería ambientales_ES
dc.subject.otherEvaporative cooling HVACes_ES
dc.subject.otherEnergy savinges_ES
dc.subject.otherDecarbonisationes_ES
dc.subject.otherLow carbon buildinges_ES
dc.titleUse of Semi-Indirect Evaporative Cooling in HVAC systems: experimental studyes_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication13b6551b-f454-4a54-8ef4-e59f1fdbcc58
relation.isAuthorOfPublication.latestForDiscovery13b6551b-f454-4a54-8ef4-e59f1fdbcc58

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Use of Semi Indirect Evaporative Cooling in HVAC systems.pdf
Size:
4.55 MB
Format:
Adobe Portable Document Format
Description:
Artículo principal
Download

Description: Artículo principal

Collections