Determination of Pb using F3eO4 GO join to DPTH for ferrofluid based dispersive solid phase extraction

Loading...
Thumbnail Image

Identifiers

Publication date

Reading date

Collaborators

Advisors

Tutors

Editors

Journal Title

Journal ISSN

Volume Title

Publisher

Metrics

Google Scholar

Share

Research Projects

Organizational Units

Journal Issue

Department/Institute

Abstract

In this work has been described a green and rapid method the synthesis of Fe3O4@GO nanospheres via chemical covalent bonding method. The Fe3O4@GO DPTH was applied to ferrofluid based dispersive solid phase extraction of lead as a model analyte using an ionic liquid carrier. The ferro fluid allows the rapid extraction of lead ions using a low amount of sorbent material. Besides, the magnetic separation greatly improved the separation rate. The presented method is highly time saving due to the high dispersion of the sorbent in the aqueous phase and also there is no need to shake the sample solution. The other benefits of the proposed methods are simplicity of operation, low cost, high sorption capacity, high recovery and high preconcentration. In order to optimize the method the following parameters were studied: sample solution pH, concentration of DPTH, extraction time, amount of sorbent, desorption conditions, influence of ionic strength, and tolerance of potentially interfering ions. The sample or standard solution containing Pb(II), DPTH (0.05% ethanol w/v), NaCl (0.5 %, w/v) and buffer (pH = 5.6) was poured into high volume. Then 240 µL of ferrofluid was injected rapidly into the sample solution through a syringe. Thereupon, a dark cloudy suspension was formed, ferrofluid was dispersed thoroughly in solution and the complex of Pb-DPTH was extracted in a few seconds. Subsequently, a strong magnet was placed at the bottom of the tube to let the extractant settle. After about 3 min, the solution became clear and the supernatant was discarded simply by decanting it. Afterwards, the magnet was removed and 1 mL of nitric acid (2.0 mol L−1) was introduced to the vial to desorb the Pb by sonication. Finally, the sorbent was separated by positioning the magnet to the outside of the tube and the concentration of Pb in acidic aqueous phase was determined by ETAAS.

Description

Bibliographic citation

Endorsement

Review

Supplemented By

Referenced by

Creative Commons license

Except where otherwised noted, this item's license is described as Attribution-NonCommercial-NoDerivatives 4.0 Internacional