Radiation dose assessment of 7Be and activated corrosion products present in the hydrogen trap of IFMIF-DONES lithium system

dc.centroFacultad de Cienciases_ES
dc.contributor.authorMartínez-Serrano, José Javier
dc.contributor.authorQiu, Yuefeng
dc.contributor.authorDézsi, Tomás
dc.contributor.authorNitti, Francesco Saverio
dc.contributor.authorIbarra, Ángel
dc.date.accessioned2024-02-22T08:45:42Z
dc.date.available2024-02-22T08:45:42Z
dc.date.issued2024-02-17
dc.departamentoFísica Aplicada I
dc.description.abstractThe radiological impact that 7Be and activated corrosion products (ACP) dissolved in Li could have in normal operation and maintenance in the surroundings of the hydrogen trap (HT) of future IFMIF-DONES facility has been assessed. Ambient dose equivalent rates were calculated with radiation transport program MCNP at half height of trap. Four different Y contents were considered in the trap: 1, 3, 5 and 8 kg. In normal operation dose rates in the range 13.7–15.1 mSv/h have been found in contact with the trap and 0.28–0.31 mSv/h at 1 m of the trap. 7Be has a very low contribution to dose (3–3.7 µSv/h). Dose simulations have shown that a concrete wall 30 cm thick can reduce dose rates to acceptable dose limits. In maintenance operation the trap is drained and Li film remains attached to Y pebbles. Three possible Li film thickness have been considered: 10, 50 and 100 µm. Estimated 7Be activity is below exemption limits during maintenance. Assessed dose rates are in the range 34–1420 µSv/h at contact with the trap and a maximum of 10.9 µSv/h at 1 m of the trap.es_ES
dc.description.sponsorshipFunding for open access charge: Universidad de Málaga/CBUA.es_ES
dc.identifier.citationJ. Javier Martínez-Serrano, Yuefeng Qiu, Tamás Dézsi, Francesco Saverio Nitti, Angel Ibarra, Radiation dose assessment of 7Be and activated corrosion products present in the hydrogen trap of IFMIF-DONES lithium system, Fusion Engineering and Design, Volume 201, 2024, 114269, ISSN 0920-3796, https://doi.org/10.1016/j.fusengdes.2024.114269es_ES
dc.identifier.doi10.1016/j.fusengdes.2024.114269
dc.identifier.urihttps://hdl.handle.net/10630/30590
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectRadiaciónes_ES
dc.subjectCorrosiónes_ES
dc.subjectHidrógenoes_ES
dc.subject.otherAmbient dose equivalent ratees_ES
dc.subject.otherHydrogen trapes_ES
dc.subject.other7Bees_ES
dc.subject.otherActivated corrosion productes_ES
dc.subject.otherIFMIF-DONESes_ES
dc.titleRadiation dose assessment of 7Be and activated corrosion products present in the hydrogen trap of IFMIF-DONES lithium systemes_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication2bde66eb-67cc-444f-894d-b2c569bb7aa2
relation.isAuthorOfPublication.latestForDiscovery2bde66eb-67cc-444f-894d-b2c569bb7aa2

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S0920379624001224-main.pdf
Size:
1.24 MB
Format:
Adobe Portable Document Format
Description:

Collections