Comparison of kinematic variables obtained by inertial sensors among stroke survivors and healthy older adults in the Functional Reach Test: cross-sectional study

dc.contributor.authorMerchán‐Baeza, José Antonio
dc.contributor.authorGonzález-Sánchez, Manuel
dc.contributor.authorCuesta-Vargas, Antonio
dc.date.accessioned2025-02-14T08:02:32Z
dc.date.available2025-02-14T08:02:32Z
dc.date.issued2015-05-30
dc.departamentoFisioterapia
dc.description.abstractBackground: Balance dysfunction is one of the most common problems in people who suffer stroke. To parameterize functional tests standardized by inertial sensors have been promoted in applied medicine. The aim of this study was to compare the kinematic variables of the Functional Reach Test (FRT) obtained by two inertial sensors placed on the trunk and lumbar region between stroke survivors (SS) and healthy older adults (HOA) and to analyze the reliability of the kinematic measurements obtained. Methods: Cross-sectional study. Five SS and five HOA over 65. A descriptive analysis of the average range as well as all kinematic variables recorded was developed. The intrasubject and intersubject reliability of the measured variables was directly calculated. Results: In the same intervals, the angular displacement was greater in the HOA group; however, they were completed at similar times for both groups, and HOA conducted the test at a higher speed and greater acceleration in each of the intervals. The SS values were higher than HOA values in the maximum and minimum acceleration in the trunk and in the lumbar region. Conclusions: The SS show less functional reach, a narrower, slower and less accelerated movement during the FRT execution, but with higher peaks of acceleration and speed when they are compared with HOA.es_ES
dc.identifier.citationMerchán-Baeza JA, González-Sánchez M, Cuesta-Vargas AI. Comparison of kinematic variables obtained by inertial sensors among stroke survivors and healthy older adults in the Functional Reach Test: cross-sectional study. Biomed Eng Online. 2015 May 30;14:49. doi: 10.1186/s12938-015-0047-z. PMID: 26025461; PMCID: PMC4448179.es_ES
dc.identifier.doi10.1186/s12938-015-0047-z
dc.identifier.urihttps://hdl.handle.net/10630/37857
dc.language.isoenges_ES
dc.publisherBMC Springer Naturees_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectCinemáticaes_ES
dc.subjectEnfermos cerebrovasculareses_ES
dc.subject.otherInertial sensores_ES
dc.subject.otherFunctional Reach Testes_ES
dc.subject.otherStroke survivorses_ES
dc.subject.otherHealthy older adultses_ES
dc.subject.otherKinematic variableses_ES
dc.subject.otherReliabilityes_ES
dc.titleComparison of kinematic variables obtained by inertial sensors among stroke survivors and healthy older adults in the Functional Reach Test: cross-sectional studyes_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationd1d67599-b8c6-4fc4-834d-eeeae4eef078
relation.isAuthorOfPublication94126d4b-371d-4727-a252-f4182972d4b6
relation.isAuthorOfPublication.latestForDiscoveryd1d67599-b8c6-4fc4-834d-eeeae4eef078

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2015 Comparison of kinematic variables obtained by inertial sensors among stroke survivors and healthy older adults in the Functional Reach Test cross‑sectional study.pdf
Size:
1.41 MB
Format:
Adobe Portable Document Format
Description:

Collections