Unestable knee osteochondritis dissecans: Arthroscopic fixation with bio-absorbable device

dc.centroFacultad de Medicinaes_ES
dc.contributor.authorBogallo, José Manuel
dc.contributor.authorGodino Izquierdo, Manuel
dc.contributor.authorDalla-Rosa, Jaime
dc.contributor.authorRamos González, Laura
dc.contributor.authorArjona Diaz, Montserrat
dc.contributor.authorGuerado-Parra, Enrique
dc.date.accessioned2024-12-10T10:36:58Z
dc.date.available2024-12-10T10:36:58Z
dc.date.issued2021-11
dc.departamentoEspecialidades Quirúrgicas, Bioquímica e Inmunología
dc.description.abstractIntroduction Knee Ostheochondritis Dissecans is an osteochondral disease, whose treatment is still debated. The purpose this study was to analyze the patients attached with bioabsorbable nail, assisted by arthroscopy. Material and method Analysis was performed using median and interquartile range (P25–P75), with a follow-up of 9 patients (10 knees) operated for stage III osteochondral lesions. After a minimum of 12 months, the KOOS, IKDC, satisfaction questionnaires were evaluated and a MR control was performed. Results Bone healing was observed in 80% of patients in the first year, with a delay in union in 20%. The median for age was 15 years. The average follow-up was 5′93 years. All cases were located in the internal condyle. The OCD lesions did not show comminution or necrosis. The 40% of stable lesions, according to preoperative MR, were unestable in arthroscopy and it were attached with internal nail. Two groups of osteochondral lesions were differentiated: juvenile OCD (60%) and adult OCD (40%); all of them were stage III lesions. IKDC questionnaire results were an improvement of 29′5 (22′25, 37′52). In the KOOS questionnaire, an improvement was obtained in symptoms of 18′07, in pain of 29′12, in daily living 25′53, in function (sports, recreational activities) of 35 and in quality of life of 34′42. Conclusions The bioabsorbable nail is a valid, reproducible option for unestable entire lesions, with an improvement in function, quality of life, and with a low rate of complications.es_ES
dc.identifier.citationBogallo JM, Godino Izquierdo M, Dalla-Rosa J, Ramos González L, Arjona Diaz M, Guerado E. Osteocondritis disecante inestable de rodilla: fijación artroscópica con implante bioabsorbible. Rev Esp Cir Ortop Traumatol. 2021;65:407–415es_ES
dc.identifier.doi10.1016/j.recote.2021.08.002
dc.identifier.urihttps://hdl.handle.net/10630/35546
dc.language.isospaes_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOsteocondritis disecantees_ES
dc.subject.otherOsteochondritis dissecanses_ES
dc.subject.otherBioabsorbablees_ES
dc.subject.otherFixationes_ES
dc.subject.otherJuveniles_ES
dc.subject.otherKneees_ES
dc.titleUnestable knee osteochondritis dissecans: Arthroscopic fixation with bio-absorbable devicees_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication19893c94-01fa-46f5-b040-a588016d1e32
relation.isAuthorOfPublication.latestForDiscovery19893c94-01fa-46f5-b040-a588016d1e32

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
secot_2021_65_408_416.pdf
Size:
586.25 KB
Format:
Adobe Portable Document Format
Description:
Artículo principal
Download

Description: Artículo principal

Collections