Rapid magnetic microextraction to preconcentrate and determinate cadmium from environmental samples

dc.centroFacultad de Cienciasen_US
dc.contributor.authorMontoro-Leal, Pablo
dc.contributor.authorGarcía-Mesa, Juan Carlos
dc.contributor.authorLópez-Guerrero, María del Mar
dc.contributor.authorSiles-Cordero, María Teresa
dc.contributor.authorVereda-Alonso, Elisa Isabel
dc.contributor.authorGarcía-de-Torres, Amparo
dc.contributor.authorCano-Pavón, José Manuel
dc.date.accessioned2019-05-29T08:04:39Z
dc.date.available2019-05-29T08:04:39Z
dc.date.created2019-06
dc.date.issued2019-05-29
dc.departamentoQuímica Analítica
dc.description.abstractA novel and greener ultrasonically assisted/modified cloud point extraction procedure for the preconcentration and extraction of trace cadmium from environmental samples was developed. The sorbent material was fabricated by scattering of magnetic iron nanoparticles (MNPs) over graphene oxide (GO) to obtain magnetic graphene oxide (MGO). The material was suspended in the ionic liquid 1-n-butyl-3-metilimidazolium tetrafluoroborate [BMIM][BF4]. The obtained stable colloidal suspension is named ferrofluid. GO presents excellent adsorbent properties for organic species due to the presence of the electronic π system. For this reason, the organic ligand [1,5-bis-(2-dipyridyl) methylene] thiocarbonohydrazide (DPTH) was used in order to form an organic complex of Cd. Once the DPTH ligand has been added to sample, the ferrofluid was injected and finely dispersed in the sample solution in order to extract the formed chelate as shown in Fig. 1. The complete adsorption of the quelate took place within few seconds, after that the solid was separated from the solution with the aid of a strong magnet. Cadmium ions were desorbed from the material with 1 mL of 5% acid nitric solution and quantified by electrothermal atomic absorption spectrometry (ETAAS). The main parameters affecting the extraction and the furnace program were optimized using one-at-time method. The analytical performance under optimum conditions are the following: LOD: 0.005 µg/L, LOQ: 0.017 µg/L. Linear calibration: 0-0.25 µg/L and EF: 200. The reliability of the developed procedure was tested by relative standard deviation (% RSD), which was found to be < 5% (1.3%). The performance of the proposed procedure was checked by applying to certified reference material and spiking standard in real samplesen_US
dc.description.sponsorshipUniversidad de Málaga. Campus de Excelencia Internacional Andalucía Tech.en_US
dc.identifier.urihttps://hdl.handle.net/10630/17736
dc.language.isoengen_US
dc.relation.eventdateJunio 2019en_US
dc.relation.eventplaceSantanderen_US
dc.relation.eventtitleANQUE2019en_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCadmio - Aspectos ambientalesen_US
dc.subjectCadmio - Capturaen_US
dc.subjectÓxido de grafenoen_US
dc.subjectFerrofluidosen_US
dc.subject.otherferrofluiden_US
dc.subject.otherGRAFENE OXIDEen_US
dc.titleRapid magnetic microextraction to preconcentrate and determinate cadmium from environmental samplesen_US
dc.typeconference outputen_US
dspace.entity.typePublication
relation.isAuthorOfPublication79951f8b-a0de-4c85-9aa0-545906d745fe
relation.isAuthorOfPublication98eedf62-d065-420d-af2c-8094def4bcd4
relation.isAuthorOfPublicationa33d331d-0317-4e4d-8473-4155d01e910c
relation.isAuthorOfPublicationbd094fe0-6e72-4cf0-be03-4b7ce250aae2
relation.isAuthorOfPublication5045eea4-1875-4817-9627-24885bccd807
relation.isAuthorOfPublication.latestForDiscovery79951f8b-a0de-4c85-9aa0-545906d745fe

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Montoro Leal Pablo.pdf
Size:
281.92 KB
Format:
Adobe Portable Document Format
Description: