Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study.

dc.centroFacultad de Ciencias de la Saludes_ES
dc.contributor.authorAlabau-Dasi, Raquel
dc.contributor.authorDomínguez-Maldonado, Gabriel
dc.contributor.authorOrtega-Ávila, Ana Belén
dc.contributor.authorGordillo-Fernández, Luis
dc.contributor.authorOrtiz-Romero, Mercedes
dc.contributor.authorMelchor-Rodríguez, Juan Manuel
dc.date.accessioned2025-04-07T09:39:23Z
dc.date.available2025-04-07T09:39:23Z
dc.date.issued2024-10-05
dc.departamentoEnfermeríaes_ES
dc.description.abstractBackground: It is important to highlight the advantages of ultrasound in assessing muscular and tendinous behavior due to its non-invasive nature and capacity for dynamic studies. However, evaluating tendons via ultrasound can be challenging given the complexity of anisotropic phenomena related to collagen fiber arrangement. This study aims to validate the reliability of fixed ultrasound compared to manual acquisition in measuring Achilles tendon thickness. Method: Twenty participants, six men and fourteen women, were recruited. Ultrasound was used to measure the Achilles tendon’s thickness at two specific points (4 and 6 cm from the calcaneal insertion of the Achilles tendon). The measurements were conducted by two examiners, one with previous experience and another without. Results: The measurements at 6 cm from the calcaneal insertion showed α = 0.996, α = 0.998 for measurements at 4 cm using manual acquisition, and α = 0.997 for measurements with fixed ultrasound at rest. For the weight-bearing and ankle dorsiflexion measurements, the reliability was excellent (α = 0.999 and α = 1.000). Conclusions: The findings demonstrated excellent reliability in the ultrasound measurements of the Achilles tendon’s thickness, even when performed by different evaluators and under load-bearing conditions. This study suggests the clinical utility of assessing anatomical structures under load, enhancing ultrasound’s applicability beyond the examination table. It is concluded that fixed ultrasound acquisition exhibits excellent reliability in measuring the Achilles tendon’s thickness, offering potential benefits for precise diagnosis of pathologies, planning surgical interventions, and reducing possible errors related to operator variability.es_ES
dc.identifier.citationAlabau-Dasi R, Dominguez-Maldonado G, Ortega-Avila AB, Gordillo-Fernandez LM, Ortiz-Romero M, Melchor-Rodriguez JM, Gijon-Nogueron G. Validation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study. Diagnostics (Basel). 2024 Oct 5;14(19):2221. doi: 10.3390/diagnostics14192221. PMID: 39410625; PMCID: PMC11476014.es_ES
dc.identifier.doi10.3390/diagnostics14192221
dc.identifier.urihttps://hdl.handle.net/10630/38387
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAttribution 4.0 Internacional
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectAquiles, Tendón de - Diagnósticoes_ES
dc.subject.otherAchilleses_ES
dc.subject.otherReliabilityes_ES
dc.subject.otherTendones_ES
dc.subject.otherUltrasonographyes_ES
dc.subject.otherValidationes_ES
dc.titleValidation of Fixed Ultrasonography for Achilles Tendon Assessment: A Reliability Study.es_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication3a9cd5a8-3920-4f3c-a97b-cab83afc8fff
relation.isAuthorOfPublication0f231f4d-baaf-40e3-a2d7-1f45aeadb7d0
relation.isAuthorOfPublication.latestForDiscovery3a9cd5a8-3920-4f3c-a97b-cab83afc8fff

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
diagnostics-14-02221.pdf
Size:
1.87 MB
Format:
Adobe Portable Document Format
Description:

Collections