Detailed and simplified models of a terminal unit that combines an UFAD system with a floor cooling

dc.centroEscuela de Ingenierías Industrialeses_ES
dc.contributor.authorAtienza-Márquez, Antonio
dc.contributor.authorFernández-Hernández, Francisco Ángel
dc.contributor.authorDomínguez-Muñoz, Fernando
dc.contributor.authorCejudo-López, José Manuel
dc.date.accessioned2024-09-24T09:37:27Z
dc.date.available2024-09-24T09:37:27Z
dc.date.issued2018
dc.departamentoIngeniería Mecánica, Térmica y de Fluidos
dc.description.abstractThis paper analyses the thermal behaviour of an underfloor air distribution system (UFAD) combined with a floor cooling, focusing on the thermal decay (TD). Two new models were implemented: a detailed model based on the convective heat transfer coefficient inside the plenum, and a simplified model based on the bypass factor. To validate the models we performed three experiments. Both, detailed and simplified models, reproduce well the measured TD. The maximum relative errors between the predicted and measured TD were 8.4% (transient state) and 1.3% (steady state). Although differences were higher at transient regimen, the terminal unit is designed to operate with smooth changes of the boundary conditions. As the error obtained by detailed and simplified models was near identical, the model based on the bypass factor is recommended because of its simplicity. A sensitivity analysis was performed. We evaluated: (1) the TD as a function of the supply air temperature and air flow rate, (2) the cooling capacity of the floor, and (3) the cooling capacity of the ventilation air. The paper concludes with a nomographic design chart that brings together all the features of the terminal unit, allowing a quick selection of the operating parameters.es_ES
dc.identifier.citationAntonio Atienza-Márquez, Francisco Fernández-Hernández, Fernando Domínguez-Muñoz, José Manuel Cejudo-López, Detailed and simplified models of a terminal unit that combines an UFAD system with a floor cooling, Applied Thermal Engineering, Volume 129, 2018, Pages 1079-1091, ISSN 1359-4311, https://doi.org/10.1016/j.applthermaleng.2017.10.093.es_ES
dc.identifier.doi10.1016/j.applthermaleng.2017.10.093
dc.identifier.urihttps://hdl.handle.net/10630/32991
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopen accesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectEdificios - Calefacción y ventilaciónes_ES
dc.subjectCalefacción radiantees_ES
dc.subjectCalor - Convecciónes_ES
dc.subject.otherCooling radiant floores_ES
dc.subject.otherUnderfloor air distribution system (UFAD)es_ES
dc.subject.otherThermal decay (TD)es_ES
dc.subject.otherDesign guidelineses_ES
dc.titleDetailed and simplified models of a terminal unit that combines an UFAD system with a floor coolinges_ES
dc.typejournal articlees_ES
dc.type.hasVersionAMes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication6cff891c-5645-474b-9371-cf043c0b2b8d
relation.isAuthorOfPublication13b6551b-f454-4a54-8ef4-e59f1fdbcc58
relation.isAuthorOfPublicationacf2f5f0-1817-435f-8163-4523a8f6bbbc
relation.isAuthorOfPublication.latestForDiscovery6cff891c-5645-474b-9371-cf043c0b2b8d

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2018_ATE_129_1079-1091_Preprint.pdf
Size:
2.01 MB
Format:
Adobe Portable Document Format
Description:

Collections