Reducing measurement time in direct interface circuits for resistive sensor readout

dc.centroEscuela de Ingenierías Industrialeses_ES
dc.contributor.authorHidalgo-López, José Antonio
dc.contributor.authorSánchez-Durán, José Antonio
dc.contributor.authorOballe-Peinado, Óscar
dc.date.accessioned2025-01-10T11:43:36Z
dc.date.available2025-01-10T11:43:36Z
dc.date.issued2020-05-02
dc.departamentoElectrónica
dc.description.abstractDirect Interface Circuits (DICs) carry out resistive sensor readings using a resistance-to-time-to-digital conversion without the need for analog-to-digital converters. The main advantage of this approach is the simplicity involved in designing a DIC, which only requires some additional resistors and a capacitor in order to perform the conversion. The main drawback is the time needed for this conversion, which is given by the sum of up to three capacitor charge times and their associated discharge times. This article presents a modification of the most widely used estimation method in a resistive DIC, which is known as the Two-Point Calibration Method (TPCM), in which a single additional programmable digital device pin in the DIC and one extra measurement in each discharge cycle, made without slowing down the cycle, allow charge times to be reduced more than 20-fold to values around 2 µs. The new method designed to achieve this reduction only penalizes relative errors with a small increase of between 0.2% and 0.3% for most values in the tested resistance range.es_ES
dc.description.sponsorshipThis work was funded by the Spanish Government and by the European ERDF program funds under contract TEC2015-67642-R and by the Universidad de Málaga under program “Plan Propio 2020”.es_ES
dc.identifier.citationHidalgo-López, J. A., Sánchez-Durán, J. A., & Oballe-Peinado, Ó. (2020). Reducing Measurement Time in Direct Interface Circuits for Resistive Sensor Readout. Sensors, 20(9), 2596. https://doi.org/10.3390/s20092596es_ES
dc.identifier.doi10.3390/s20092596
dc.identifier.urihttps://hdl.handle.net/10630/36132
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectDetectoreses_ES
dc.subject.otherDirect interface circuitses_ES
dc.subject.otherCalibration methodses_ES
dc.subject.otherError analysises_ES
dc.subject.otherResistive sensores_ES
dc.subject.otherInterface sensores_ES
dc.subject.otherTime-based measurementes_ES
dc.titleReducing measurement time in direct interface circuits for resistive sensor readoutes_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication7c47e9c9-2533-4a7c-8df3-c53b54823a46
relation.isAuthorOfPublication26b8b990-9fa9-4f37-a1ab-d63c3619bb88
relation.isAuthorOfPublicationf46c97dc-f428-4b49-9d98-eaaf5ae974e2
relation.isAuthorOfPublication.latestForDiscovery7c47e9c9-2533-4a7c-8df3-c53b54823a46

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
sensors-20-02596.pdf
Size:
3.1 MB
Format:
Adobe Portable Document Format
Description:

Collections