İnter-rater and intra-rater reliability of the extended TUG test in elderly participants

dc.contributor.authorBedoya-Belmonte, Juan José
dc.contributor.authorRodríguez-González, María Del Mar
dc.contributor.authorGonzález-Sánchez, Manuel
dc.contributor.authorBarreda Pitarch, Jose Miguel
dc.contributor.authorGalán Mercant, Alejandro
dc.contributor.authorCuesta-Vargas, Antonio
dc.date.accessioned2024-12-18T12:25:52Z
dc.date.available2024-12-18T12:25:52Z
dc.date.issued2020-02-13
dc.departamentoFisioterapia
dc.description.abstractBackground: To analyse the reliability, variance and execution time of the Extended Timed Up and Go (Extended TUG) test in three age groups of elderly participants (G1: 55-64 years; G2: 65-74 years; G3: 75-85 years). Methods: An analytical cross-sectional study of 114 recruited participants (63 women) of average age 70.17 (± 7.3) years was undertaken. Each participant performed the Extended TUG three consecutive times, with a rest break between tests of 120 s. Both the intragroup and intergroup reliability of the measurements in the Extended TUG were analysed. Results: The reliability of the Extended TUG test is excellent for the first and second decades but drops down to good for the third decade. Specifically, intragroup reliability ranged from 0.784 for G3 to 0.977 for G1 (G2 = 0.858). Intergroup reliability, compared with intragroup reliability, was slightly lower, ranging between 0.779 for G3 and 0.972 for G1 (G2 = 0.853). Conclusion: The reliability of the Extended TUG test progressively decreases with increasing age, being excellent for the younger age groups and good for the oldest age group.es_ES
dc.identifier.citationBedoya-Belmonte, J.J., Rodríguez-González, M.d.M., González-Sánchez, M. et al. İnter-rater and intra-rater reliability of the extended TUG test in elderly participants. BMC Geriatr 20, 56 (2020). https://doi.org/10.1186/s12877-020-1460-0es_ES
dc.identifier.doi10.1186/s12877-020-1460-0
dc.identifier.urihttps://hdl.handle.net/10630/35759
dc.language.isoenges_ES
dc.publisherBMC Springer Naturees_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectFragilidad - Testses_ES
dc.subject.otherAgedes_ES
dc.subject.otherCross-Sectional Studieses_ES
dc.subject.otherFemalees_ES
dc.subject.otherHumanses_ES
dc.subject.otherMalees_ES
dc.subject.otherMiddle Agedes_ES
dc.subject.otherPhysical Therapy Modalitieses_ES
dc.subject.otherReproducibility of Resultses_ES
dc.titleİnter-rater and intra-rater reliability of the extended TUG test in elderly participantses_ES
dc.typejournal articlees_ES
dc.type.hasVersionVoRes_ES
dspace.entity.typePublication
relation.isAuthorOfPublicationd1d67599-b8c6-4fc4-834d-eeeae4eef078
relation.isAuthorOfPublication94126d4b-371d-4727-a252-f4182972d4b6
relation.isAuthorOfPublication.latestForDiscoveryd1d67599-b8c6-4fc4-834d-eeeae4eef078

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
12877_2020_Article_1460.pdf
Size:
523.7 KB
Format:
Adobe Portable Document Format
Description:

Collections