dc.description.abstractComplex functional materials consisting of bioactive molecules immobilized on solid supports present potential applications in biosensoring. Advances in the fabrication of these surface materials are of growing interest for antibody-based diagnosis. This work exploits dendrimers as versatile nanostructures for templating sensor surfaces and the critical role of the immobilization protocol in the solid supports cellulose and zeolites, of organic and inorganic composition respectively. The fabrication and characterization, including the degree of functionalization and reproducibility, of different nanostructured materials are described. To validate the approach, the fabricated supports were further used as a solid phase for developing a radioimmunoassay to detect immunoglobulin E (IgE) specific to penicillin, the antibody involved in immediate allergy responses to this drug. The dendrimer-modified supports provide assays with significantly enhanced sensitivity, as well as increase the availability of biomolecules for specific interaction and minimize nonspecific adsorptions through appropriate functionalization protocols in each case. The manufacturing methodology involved the use of a long, flexible hydrophilic spacer in the cellulose materials, and a higher surface density of the immobilized dendrimers in the zeolite crystals. The ability of hybrid zeolite materials in such biosensing applications was evaluated for the first time. The assays were validated in human serum samples from patients allergic to penicillin and from non-allergic controls. The specificity and improved sensitivity of the dendrimer- modified supports make these strategies versatile for different bioactive molecules and could have significant implications for the quantification of a wide range of specific IgE antibodies and other biomolecules of diagnostic interest.es_ES
dc.identifier.doi10.2174/0929867311209024942
dc.identifier.urihttps://hdl.handle.net/10630/33107
dc.language.isoenges_ES
dc.publisherBentham Sciencees_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectBiosensoreses_ES
dc.subject.otherAllergyes_ES
dc.subject.otherBiosensores_ES
dc.subject.otherDendrimeres_ES
dc.subject.otherZeolitees_ES
dc.titleDendrimer-Modified Solid Supports: Nanostructured Materials with Potential Drug Allergy Diagnostic Applicationses_ES
dc.typejournal articlees_ES
dc.type.hasVersionSMURes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication2dd035c6-77e1-43d2-b0d8-9054c037065f
relation.isAuthorOfPublication024963b0-e231-43fe-b99d-2fdcea74ee78
relation.isAuthorOfPublication41ad1836-4116-4322-9338-fe908247f628
relation.isAuthorOfPublication98747537-47b0-44b3-8957-b82ffe8b4cf3
relation.isAuthorOfPublication.latestForDiscovery2dd035c6-77e1-43d2-b0d8-9054c037065f

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2012 - Ruiz-Sanchez et al. - Current medicinal chemistry v.pdf
Size:
981.6 KB
Format:
Adobe Portable Document Format
Description:

Collections