Reliability and parameterization of Romberg Test in people who have suffered a stroke

dc.centroFacultad de Ciencias de la Saludes_ES
dc.contributor.authorPérez-Cruzado, David Francisco
dc.contributor.authorGonzález-Sánchez, Manuel
dc.contributor.authorCuesta-Vargas, Antonio
dc.date.accessioned2014-10-22T09:24:35Z
dc.date.available2014-10-22T09:24:35Z
dc.date.created2014
dc.date.issued2014-10-22
dc.departamentoFisioterapia
dc.description.abstractAIM: To analyze the reliability and describe the parameterization with inertial sensors, of Romberg test in people who have had a stroke. METHODS: Romberg's Test was performed during 20 seconds in four different setting, depending from supporting leg and position of the eyes (opened eyes / dominant leg; closed eyes / dominant leg; opened eyes / non-dominant leg; closed eyes / non-dominant leg) in people who have suffered a stroke over a year ago. Two inertial sensors (sampling frequency 180Hz) were placed in lumbar (L5-S1) and in the trunk (T7). The test was performed three times for the four different settings. The outcome variables were extracted in each of the axes (X, Y, Z) (figure 1). We considered as the maximum, minimum and mean velocity and the magnitude of the angular displacement for each of the sensors (Figure 2 shows an example of direct extraction of variables). Statistical Analysis: descriptive analysis of all outcome variables for each axis and sensor. Further analysis of the internal consistency of the measure was performed by analysis interclass correlation (ICC) with a confidence interval of 95%. RESULTS: Values obtained after statistical analysis show levels of reliability ranging from 0.61 (Z axis speed - eyes closed / nondominant leg) and 0.92 (Y axis offset - opened eyes / dominant leg). The descriptive results of all outcome variables are shown in Table 1. CONCLUSION: Making inertial sensors in trunk and / or lumbar, inertial sensors are reliable tools for parameterizing Romberg test in different settings in people who have suffered stroke over a year ago.es_ES
dc.description.sponsorshipUniversidad de Málaga. Campus de Excelencia Internacional Andalucía Tech.es_ES
dc.identifier.urihttp://hdl.handle.net/10630/8279
dc.language.isoenges_ES
dc.relation.eventdateJulio, 2014es_ES
dc.relation.eventplaceRoma, Italiaes_ES
dc.relation.eventtitleXX Congress of the Internatonal Society of Electrophysiology and Kinesiologyes_ES
dc.rights.accessRightsopen accesses_ES
dc.subjectElectrofisiologíaes_ES
dc.subject.otherReliabilityes_ES
dc.subject.otherParametrisationes_ES
dc.subject.otherRomberg Testes_ES
dc.subject.otherStrokees_ES
dc.titleReliability and parameterization of Romberg Test in people who have suffered a strokees_ES
dc.typeconference outputes_ES
dspace.entity.typePublication
relation.isAuthorOfPublication636ed082-6d1a-4c86-abe1-5a1dc630a6a7
relation.isAuthorOfPublicationd1d67599-b8c6-4fc4-834d-eeeae4eef078
relation.isAuthorOfPublication94126d4b-371d-4727-a252-f4182972d4b6
relation.isAuthorOfPublication.latestForDiscovery636ed082-6d1a-4c86-abe1-5a1dc630a6a7

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
RELIABILITY AND PARAMETERIZAT.pdf
Size:
190.71 KB
Format:
Adobe Portable Document Format