<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-28T11:15:51Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/11663" metadataPrefix="mods">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/11663</identifier><datestamp>2026-02-03T11:59:11Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><mods:mods xmlns:doc="http://www.lyncode.com/xoai" xmlns:mods="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-1.xsd">
   <mods:name>
      <mods:namePart>Gómez-de-la-Torre, María de los  Ángeles</mods:namePart>
   </mods:name>
   <mods:name>
      <mods:namePart>Cabeza-Díaz, Aurelio</mods:namePart>
   </mods:name>
   <mods:name>
      <mods:namePart>García-Aranda, Miguel Ángel</mods:namePart>
   </mods:name>
   <mods:name>
      <mods:namePart>León-Reina, Laura</mods:namePart>
   </mods:name>
   <mods:extension>
      <mods:dateAvailable encoding="iso8601">2016-06-27T11:09:49Z</mods:dateAvailable>
   </mods:extension>
   <mods:extension>
      <mods:dateAccessioned encoding="iso8601">2016-06-27T11:09:49Z</mods:dateAccessioned>
   </mods:extension>
   <mods:originInfo>
      <mods:dateIssued encoding="iso8601">2016-06-27</mods:dateIssued>
   </mods:originInfo>
   <mods:identifier type="uri">http://hdl.handle.net/10630/11663</mods:identifier>
   <mods:identifier type="orcid">http://orcid.org/0000-0001-5481-7268</mods:identifier>
   <mods:abstract>X-Ray Powder Diffraction (XRPD) laboratory is a facility placed at Servicios Centrales de apoyo a la Investigación (SCAI) at University of Malaga (UMA) http://www.scai.uma.es/. This facility has three XRPD diffractometers and a diffractometer to measure high-resolution thin-films.&#xd;
X´Pert PRO MPD from PANalytical. This is a bragg-brentano (theta/2theta) with reflection geometry diffractometer which allows to obtain high resolution XRPD data with strictly monochromatic CuKα1 radiation (λ=1.54059Å) [Ge(111) primary monochromator] and an automatic sample charger. Moreover, it has parallel monochromatic CuKα1 radiation (λ=1.54059Å) with an hybrid Ge(220) monochromator for capillary and multiproposal (bulk samples up to 1 Kg) sample holders. The HTK1200N chamber from Anton Paar allows collecting high resolution high temperature patterns. &#xd;
EMPYREAN from PANalytical. This diffractometer works in reflection and transmission geometries with theta/theta goniometer, using CuKα1,2 radiation (λ=1.5418Å), a focusing X-ray mirror and a ultra-fast PIXCEL 3D detector with 1D and 2D collection data modes (microstructural and preferred orientation analysis). Moreover, the TTK450N chamber allows low temperature and up to 450ºC studies.&#xd;
A D8 ADVANCE (BRUKER) was installed in April 2014. It is the first diffractometer in Europe equipped with a Johansson Ge(111) primary monochromator, which gives a strictly monochromatic Mo radiation (λ=0.7093 Å) [1]. It works in transmission mode (with a sample charger) with this high resolution configuration. XRPD data suitable for PDF (Pair Distribution Function) analysis can be collected with a capillary sample holder, due to the high energy and high resolution capabilities of this diffractometer. Moreover, it has a humidity chamber MHC-trans from Anton Paar working on transmission mode with MoKα1 (measurements can be collected at 5 to 95% of relative humidity (from 20 to 80 ºC) and up to 150ºC [2]). Furthermore, this diffractometer also has a reaction chamber XRK900 from Anton Paar (which uses CuKα1,2 radiation in reflection mode), which allows data collection from room temperature to 900ºC with up to 10 bar of different gases.&#xd;
Finally, a D8 DISVOVER A25 from BRUKER was installed on December 2014. It has a five axis Euler cradler and optics devices suitable for high resolution thin film data collection collected in in-plane and out-of-plane modes. To sum up, high-resolution thin films, microstructural, rocking-curve, Small Angle X-ray Scattering (SAXS), Grazing incident SAXS (GISAXS), Ultra Grazing incident diffraction (Ultra-GID) and microdiffraction measurements can be performed with the appropriated optics and sample holders.&#xd;
&#xd;
[1] L. León-Reina, M. García-Maté, G. Álvarez-Pinazo, I. Santacruz, O. Vallcorba, A.G. De la Torre, M.A.G. Aranda “Accuracy in Rietveld quantitative phase analysis: a comparative study of strictly monochromatic Mo and Cu radiations” J. Appl. Crystallogr. 2016, 49, 722-735.&#xd;
&#xd;
[2] J. Aríñez-Soriano, J. Albalad, C. Vila-Parrondo, J. Pérez-Carvajal, S. Rodríguez-Hermida, A. Cabeza, F. Busqué, J. Juanhuix, I. Imaz, Daniel Maspoch “Single-crystal and humidity-controlled powder diffraction study of the breathing effect in a metal-organic framework upon water adsorption/desorption” Chem. Commun., 2016, DOI: 10.1039/C6CC02908F.</mods:abstract>
   <mods:language>
      <mods:languageTerm>eng</mods:languageTerm>
   </mods:language>
   <mods:accessCondition type="useAndReproduction">open access</mods:accessCondition>
   <mods:accessCondition type="useAndReproduction">by-nc-nd</mods:accessCondition>
   <mods:subject>
      <mods:topic>Rayos X - Difracción</mods:topic>
   </mods:subject>
   <mods:titleInfo>
      <mods:title>X-Ray powder diffraction laboratory @ University of Málaga (UMA)</mods:title>
   </mods:titleInfo>
   <mods:genre>conference output</mods:genre>
</mods:mods>
</metadata></record></GetRecord></OAI-PMH>