<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-28T08:51:11Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/14461" metadataPrefix="qdc">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/14461</identifier><datestamp>2026-02-03T12:15:37Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><qdc:qualifieddc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:qdc="http://dspace.org/qualifieddc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://purl.org/dc/elements/1.1/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dc.xsd http://purl.org/dc/terms/ http://dublincore.org/schemas/xmls/qdc/2006/01/06/dcterms.xsd http://dspace.org/qualifieddc/ http://www.ukoln.ac.uk/metadata/dcmi/xmlschema/qualifieddc.xsd">
   <dc:title>Caracterización no-lineal de dispositivos de un puerto basada en el principio de distorsión poli-armónica</dc:title>
   <dc:creator>Martín-Guerrero, Teresa María</dc:creator>
   <dc:creator>Entrambasaguas-Muñoz, José Tomás</dc:creator>
   <dc:creator>Camacho-Peñalosa, Carlos</dc:creator>
   <dc:subject>Circuitos eléctricos</dc:subject>
   <dcterms:abstract>In this contribution the computation of a nonlinear diode model based on the Poly-Harmonic Distortion principle is&#xd;
described. The diode is composed of a non-linear conductance shunt connected to a non-linear capacitance, both of them quasistatic.&#xd;
The procedure used to extract these parameters only requires port-voltage and -current waveforms. The computed parameters of the model at different frequencies and power levels&#xd;
are presented and have been validated by comparing them with those obtained using a commercial circuit simulation tool&#xd;
(specifically with X-parameters). Unlike commercial CAD tools or conventional measurement set-ups the proposed technique can&#xd;
easily provide all the sensitivities related to DC components.</dcterms:abstract>
   <dcterms:dateAccepted>2017-09-13T12:06:10Z</dcterms:dateAccepted>
   <dcterms:available>2017-09-13T12:06:10Z</dcterms:available>
   <dcterms:created>2017-09-13T12:06:10Z</dcterms:created>
   <dcterms:issued>2017-09-13</dcterms:issued>
   <dc:type>conference output</dc:type>
   <dc:identifier>http://hdl.handle.net/10630/14461</dc:identifier>
   <dc:language>spa</dc:language>
   <dc:relation>XXXII Simposium Nacional URSI</dc:relation>
   <dc:relation>Cartagena (Murcia)</dc:relation>
   <dc:relation>6/9/2017</dc:relation>
   <dc:rights>open access</dc:rights>
   <dc:rights>by-nc-nd</dc:rights>
</qdc:qualifieddc>
</metadata></record></GetRecord></OAI-PMH>