<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-28T15:56:18Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/17736" metadataPrefix="marc">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/17736</identifier><datestamp>2026-02-03T12:25:00Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Montoro-Leal, Pablo</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">García-Mesa, Juan Carlos</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">López-Guerrero, María del Mar</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Siles-Cordero, María Teresa</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Vereda-Alonso, Elisa Isabel</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">García-de-Torres, Amparo</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Cano-Pavón, José Manuel</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2019-05-29</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">A novel and greener ultrasonically assisted/modiﬁed cloud point extraction procedure for the preconcentration and extraction of trace cadmium from environmental samples was developed. The sorbent material was fabricated by scattering of magnetic iron nanoparticles (MNPs) over graphene oxide (GO) to obtain magnetic graphene oxide (MGO). The material was suspended in the ionic liquid 1-n-butyl-3-metilimidazolium tetrafluoroborate [BMIM][BF4]. The obtained stable colloidal suspension is named ferrofluid. GO presents excellent adsorbent properties for organic species due to the presence of the electronic π system. For this reason, the organic ligand [1,5-bis-(2-dipyridyl) methylene] thiocarbonohydrazide (DPTH) was used in order to form an organic complex of Cd. Once the DPTH ligand has been added to sample, the ferrofluid was injected and finely dispersed in the sample solution in order to extract the formed chelate as shown in Fig. 1. The complete adsorption of the quelate took place within few seconds, after that the solid was separated from the solution with the aid of a strong magnet. Cadmium ions were desorbed from the material with 1 mL of 5% acid nitric solution and quantified by electrothermal atomic absorption spectrometry (ETAAS). &#xd;
The main parameters affecting the extraction and the furnace program were optimized using one-at-time method. The analytical performance under optimum conditions are the following: LOD: 0.005 µg/L, LOQ: 0.017 µg/L. Linear calibration: 0-0.25 µg/L and EF: 200. The reliability of the developed procedure was tested by relative standard deviation (% RSD), which was found to be &lt; 5% (1.3%). The performance of the proposed procedure was checked by applying to certiﬁed reference material and spiking standard in real samples</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">https://hdl.handle.net/10630/17736</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Cadmio - Aspectos ambientales</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Cadmio - Captura</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Óxido de grafeno</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Ferrofluidos</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Rapid magnetic microextraction to preconcentrate and determinate cadmium from environmental samples</subfield>
   </datafield>
</record>
</metadata></record></GetRecord></OAI-PMH>