<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-01T02:17:12Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/17881" metadataPrefix="rdf">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/17881</identifier><datestamp>2026-02-03T12:09:55Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
   <ow:Publication rdf:about="oai:riuma.uma.es:10630/17881">
      <dc:title>Analysis of a PV Window for Building Integrated Photovoltaic (BIPV) Applications</dc:title>
      <dc:creator>Serrano-Casares, Francisco Víctor</dc:creator>
      <dc:creator>Navas Frías, Verónica</dc:creator>
      <dc:description>An amorphous silicon photovoltaic module encapsulated between two transparent glass sheets, an air chamber and a second double glass sheet with an air chamber forms the photovoltaic window. Everything is framed in a PVC structure. The effective dimensions of the a-Si photovoltaic module are 0,57 m x 1,17 m, equivalent to a standard measurement of 0,60 m x 1,20 m. &#xd;
To know the electrical characteristics of PV window in standard test conditions, a test in accordance with IEC standard 61646 and 61215 was carried out.  A peak power of 50,74 Wp was obtained and a power uncertainty of ± 6,78% was found. The PV window was placed in a test bench installed on the rooftop of the building of the Andalusian Institute of Renewable Energies, at Málaga (36,73 N; 4,55 W). The test bench allows an adjustment of both azimuth and inclination. A pyranometer was used to measure the global irradiance on the window plane, and a temperature sensor measures its temperature. The photovoltaic window was placed in vertical position facing South. A protocol for data collection that allows knowing the instantaneous power generated by the photovoltaic window has been developed. The irradiance received in a sunny day on the plane of the photovoltaic window was 4114 Wh/m2 and the energy produced was 71,2 Wh. These values are consistent with radiation data obtained from databases and the power value obtained from PV window under standard test conditions. &#xd;
The production of electricity, the economic savings, and CO2 emissions avoided will be analyzed if PV semi-transparent windows were used to replace the glazing skylight of the Industrial Engineering School  of Malaga. It will result a BIPV system of 122,73 kWp that could produce 198 MWh per year, save € 27738 and avoid the emission into the atmosphere of 76 tons of CO2.</dc:description>
      <dc:date>2019-06-25T09:44:47Z</dc:date>
      <dc:date>2019-06-25T09:44:47Z</dc:date>
      <dc:date>2019</dc:date>
      <dc:date>2019-06-25</dc:date>
      <dc:type>conference output</dc:type>
      <dc:identifier>https://hdl.handle.net/10630/17881</dc:identifier>
      <dc:language>eng</dc:language>
      <dc:relation>XI National and II International Congress of Engineering Thermodynamics</dc:relation>
      <dc:relation>Albacete (España)</dc:relation>
      <dc:relation>12-14 junio 2019</dc:relation>
      <dc:rights>open access</dc:rights>
   </ow:Publication>
</rdf:RDF>
</metadata></record></GetRecord></OAI-PMH>