<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-03T22:30:29Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/18382" metadataPrefix="rdf">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/18382</identifier><datestamp>2026-02-03T12:20:31Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
   <ow:Publication rdf:about="oai:riuma.uma.es:10630/18382">
      <dc:title>Contributions to displacement and resistance of the meniscus-suture complex in transtibial meniscal root repair</dc:title>
      <dc:creator>Prado-Novoa, María</dc:creator>
      <dc:creator>Pérez-Blanca, Ana</dc:creator>
      <dc:creator>Estébanez-Campos, María Belén</dc:creator>
      <dc:creator>Nadal-Martínez, Fernando</dc:creator>
      <dc:creator>Espejo-Reina, Alejandro</dc:creator>
      <dc:creator>Ceccarelli, Marco</dc:creator>
      <dc:subject>Rodillas-Lesiones y heridas-Tratamiento</dc:subject>
      <dc:subject>Biomecánica</dc:subject>
      <dc:description>This work analyses in a porcine model the contributions of meniscal tissue, suture thread and meniscus-suture interaction to the permanent displacements generated at the repaired root after surgery to re-insert the posterior meniscal root using a transtibial pullout technique. Medial porcine menisci with a single suture applied at the posterior horn were subjected to cyclic and load-to-failure tests. Elongations of the different components of the meniscus-suture complex were determined applying photogrammetry. Results showed that after low intensity cyclic loading, the main contribution to permanent root displacements was due to the thread (51.2%), while no cutting of the suture through tissue occur at the interface. Under load-to-failure conditions, suture cutting started at a significantly higher load level (Suture Retention Strength, SRS), always before and close to the first local maximum of the load-elongation curve, and progressed rapidly afterwards causing the final failure of all specimens</dc:description>
      <dc:date>2019-09-18T09:43:54Z</dc:date>
      <dc:date>2019-09-18T09:43:54Z</dc:date>
      <dc:date>2019</dc:date>
      <dc:date>2019</dc:date>
      <dc:type>conference output</dc:type>
      <dc:identifier>https://hdl.handle.net/10630/18382</dc:identifier>
      <dc:language>eng</dc:language>
      <dc:relation>8th International Conference in Mechanics and Materials in Design</dc:relation>
      <dc:relation>Bolonia, Italia</dc:relation>
      <dc:relation>Septiembre, 2019</dc:relation>
      <dc:rights>open access</dc:rights>
   </ow:Publication>
</rdf:RDF>
</metadata></record></GetRecord></OAI-PMH>