<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-01T10:17:51Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/18425" metadataPrefix="rdf">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/18425</identifier><datestamp>2026-02-03T12:08:47Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
   <ow:Publication rdf:about="oai:riuma.uma.es:10630/18425">
      <dc:title>Laser-induced breakdown spectrometry with laser pulses in femtoseconds to picoseconds regime and their influence on ablation quality</dc:title>
      <dc:creator>Manzoor, Sadia</dc:creator>
      <dc:creator>Vadillo-Pérez, José Miguel</dc:creator>
      <dc:creator>Laserna-Vázquez, José Javier</dc:creator>
      <dc:subject>Láseres</dc:subject>
      <dc:subject>Espectroscopía de plasma inducido por láser</dc:subject>
      <dc:subject>Espectroscopía de láser</dc:subject>
      <dc:description>The communication is focused on the influence of the pulse width, ranging from femtosecond to picosecond, on the&#xd;
laser – matter interaction during laser ablation of solid materials. Modifications in the stretcher-compressor do&#xd;
allow the continuous selection of amplified pulses in the range between 35 fs to 4 ps. Time constants, fluence&#xd;
threshold, and multi-channel spectra have been measured out of the generated plasmas.</dc:description>
      <dc:date>2019-09-20T11:38:37Z</dc:date>
      <dc:date>2019-09-20T11:38:37Z</dc:date>
      <dc:date>2019</dc:date>
      <dc:date>2019-09-20</dc:date>
      <dc:type>conference output</dc:type>
      <dc:identifier>https://hdl.handle.net/10630/18425</dc:identifier>
      <dc:language>eng</dc:language>
      <dc:relation>EMSLIBS 2019</dc:relation>
      <dc:relation>Brno (República Checa)</dc:relation>
      <dc:relation>Septiembre 2019</dc:relation>
      <dc:rights>http://creativecommons.org/licenses/by-nc-nd/4.0/</dc:rights>
      <dc:rights>open access</dc:rights>
      <dc:rights>Attribution-NonCommercial-NoDerivatives 4.0 Internacional</dc:rights>
   </ow:Publication>
</rdf:RDF>
</metadata></record></GetRecord></OAI-PMH>