<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-27T12:07:34Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/36997" metadataPrefix="rdf">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/36997</identifier><datestamp>2026-02-03T10:59:26Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37953</setSpec></header><metadata><rdf:RDF xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:ds="http://dspace.org/ds/elements/1.1/" xmlns:ow="http://www.ontoweb.org/ontology/1#" xmlns:rdf="http://www.openarchives.org/OAI/2.0/rdf/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/rdf/ http://www.openarchives.org/OAI/2.0/rdf.xsd">
   <ow:Publication rdf:about="oai:riuma.uma.es:10630/36997">
      <dc:title>A proposal to eliminate the impact of crosstalk on resistive sensor array readouts</dc:title>
      <dc:creator>Hidalgo-López, José Antonio</dc:creator>
      <dc:creator>Oballe-Peinado, Óscar</dc:creator>
      <dc:creator>Sánchez-Durán, José Antonio</dc:creator>
      <dc:subject>Detectores</dc:subject>
      <dc:description>Completely eliminating crosstalk effect is the most important challenge when reading a resistive sensor array with M rows and N columns. It may require complex electronics, ranging from a large number of multiplexers and switches to use of M AC voltage sources. More measurements than those considered strictly necessary, M · N, may also be required. Thus, an implementation with multiplexers and switches uses 2 · M · N measurements, while this number rises to M · N · L in the one that uses AC voltage sources, where L is the Fourier Transform length required to obtain the sensor readings. This article presents a new circuit and readout method to eliminate crosstalk that simultaneously reduces the total number of multiplexers to M + N and the number of measurements to N · (M + 1 + (N + 1)/2). The unique source of error comes from the non-idealities of the only operational amplifier used. As an added benefit, the new circuit also reduces power consumption of the array by including a single additional resistor.</dc:description>
      <dc:date>2025-01-27T07:37:19Z</dc:date>
      <dc:date>2025-01-27T07:37:19Z</dc:date>
      <dc:date>2020-06-26</dc:date>
      <dc:type>journal article</dc:type>
      <dc:identifier>J. A. H. López, Ó. Oballe-Peinado and J. A. Sánchez-Durán, "A Proposal to Eliminate the Impact of Crosstalk on Resistive Sensor Array Readouts," in IEEE Sensors Journal, vol. 20, no. 22, pp. 13461-13470, 15 Nov.15, 2020, doi: 10.1109/JSEN.2020.3005227.</dc:identifier>
      <dc:identifier>https://hdl.handle.net/10630/36997</dc:identifier>
      <dc:identifier>10.1109/JSEN.2020.3005227</dc:identifier>
      <dc:language>eng</dc:language>
      <dc:rights>open access</dc:rights>
      <dc:publisher>Institute of Electrical and Electronics Engineers (IEEE)</dc:publisher>
   </ow:Publication>