<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-30T07:49:52Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/37130" metadataPrefix="marc">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/37130</identifier><datestamp>2026-02-03T11:33:27Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37953</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">González-Infantes, Wilfredo</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Lallena, Antonio</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Alfonso, Rodolfo</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2011-05-13</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">Micro-multileaf collimators are devices that are added to LINAC heads for&#xd;
stereotactic radiosurgery. In this work, the performance of an Elekta Precise LINAC,&#xd;
with a dynamic micro-multileaf collimator manufactured by 3D-Line has been studied.&#xd;
Monte Carlo simulations based on PENELOPE code and measurements with three&#xd;
different detectors (PTW Semiflex 31010 chamber, PTW PinPoint 31016 chamber and&#xd;
PTW Diode 60008) have been carried out. Simulations were tuned by reproducing&#xd;
the experimental TPR20,10 quality index, providing a nice description of both the&#xd;
PDD curve and the transverse profiles at two depths measured. The geometry of the&#xd;
micro-multileaf collimator was tested by calculating the transmission through it and it&#xd;
was needed to reduce significantly the leaf separation indicated by the manufacturer to&#xd;
reproduce the experimental results. An approximate simulation in which the transport&#xd;
of the particles traversing the dynamic micro-multileaf collimator was described in a&#xd;
simplified way was analyzed, providing a good agreement with the full simulations.&#xd;
With the MC model fixed, output factors for various field sizes were calculated and&#xd;
compared to the experimental ones, obtaining a good agreement. PDDs and transverse&#xd;
profiles at two depths measured with the diode for small fields were well reproduced&#xd;
by the simulation, while the measurements performed with the PinPoint chamber&#xd;
showed differences in the PDDs, at large depths, and in the transverse profiles, at the&#xd;
penumbra. Monte Carlo simulations and Semiflex and diode measurements, performed&#xd;
for a 7.0 cm×7.0 cm field, were in nice agreement, while those obtained with the&#xd;
PinPoint chamber showed differences that increased with the depth in water. At&#xd;
the phantom entrance, all measurements showed non-negligible differences what made&#xd;
Monte Carlo a good option to estimate the absorbed dose in this region.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">Phys. Med. Biol. 2011. 56 3417</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">https://hdl.handle.net/10630/37130</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">10.1088/0031-9155/56/11/015</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Montecarlo, Método de</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Aceleradores lineales</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Monte Carlo simulation of the dynamic micro-multileaf collimator of a LINAC Elekta Precise using PENELOPE.</subfield>
   </datafield>
</record>
</metadata></record></GetRecord></OAI-PMH>