<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-05-27T05:24:26Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/7852" metadataPrefix="marc">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/7852</identifier><datestamp>2026-02-03T12:24:25Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">López-Claros, Marina</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Carrasco-García, Irene María</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Vadillo-Pérez, José Miguel</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Laserna-Vázquez, José Javier</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2014-07-16</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">Our communication is focused on the influence of the pulse width in the laser-matter interaction during laser ablation of solid materials. The experiments were performed with an 80 MHz, 100 nJ, 400 fs Ti-Saphire oscillator, amplified to produce an output of 3,5 mJ at 35 fs and a maximum repletion rate of 1 KHz. Modifications in the stretcher-compressor have allowed the continuous selection of amplified pulses in the range between 35 fs to 4 ps. The pulses are subjected to measurements in the autocorrelation, spectral bandwidth and energy per pulse. A 0.5 m focal-length spectrograph fitted with an intensified CCD or fast single-channel detectors is used to determine the time constants, to establish the fluence threshold, and to record multi-channel spectra from the generated plasmas. Additionally, morphological characterization making use of optical and electron microscopy were performed.&#xd;
The effect of the longer laser pulses in the laser-matter interaction - particularly in the extension of the heat-affected zone - and its implication in depth-profiling studies was also checked. For such purpose, a layered sample with a defined structure was analyzed by laser-induced breakdown spectroscopy under different pulse widths conditions. The effect on the averaged ablation rate, depth resolution and layer mixing will be commented.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">http://hdl.handle.net/10630/7852</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Espectroscopía de plasma inducido por láser</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Differential laser-matter interaction in the ablation of solid samples with laser pulses in the interval between 35 fs – 4 ps.</subfield>
   </datafield>
</record>
</metadata></record></GetRecord></OAI-PMH>