<?xml version="1.0" encoding="UTF-8"?><?xml-stylesheet type="text/xsl" href="static/style.xsl"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-06-01T19:52:48Z</responseDate><request verb="GetRecord" identifier="oai:riuma.uma.es:10630/8268" metadataPrefix="marc">https://riuma.uma.es/rest/oai/request</request><GetRecord><record><header><identifier>oai:riuma.uma.es:10630/8268</identifier><datestamp>2026-02-03T12:07:14Z</datestamp><setSpec>com_10630_2254</setSpec><setSpec>col_10630_37959</setSpec></header><metadata><record xmlns="http://www.loc.gov/MARC21/slim" xmlns:dcterms="http://purl.org/dc/terms/" xmlns:doc="http://www.lyncode.com/xoai" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
   <leader>00925njm 22002777a 4500</leader>
   <datafield ind2=" " ind1=" " tag="042">
      <subfield code="a">dc</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Merchan Baeza, Jose Antonio</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">González-Sánchez, Manuel</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="720">
      <subfield code="a">Cuesta-Vargas, Antonio</subfield>
      <subfield code="e">author</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="260">
      <subfield code="c">2014-10-22</subfield>
   </datafield>
   <datafield ind2=" " ind1=" " tag="520">
      <subfield code="a">AIM: The aim of this study is to analyse the reliability, sensitivity and specificity of the parameterisation of&#xd;
FRT using inertial sensors to record kinematic variables in subjects who have had a stroke. Our hypothesis is&#xd;
that the IS will be reliable instruments for kinematic study of the FRT.&#xd;
METHODS: This is a cross-sectional study of 5 subjects over 65 years who suffer of stroke. During the&#xd;
execution of Funtional Reach Test the subjects carried two inertial sensors, one was placed in the lumbar&#xd;
and the other in the trunk. After analysing the data obtained in the kinematic registration by inertial sensors a&#xd;
number of direct and indirect variables were obtained. The variables extracted directly from FRT through&#xd;
the IS were distance, maximun angular lumbosacral/thoracic displacement, time maximun angular&#xd;
lumbosacral/thoracic displacement, time return starting position and total time. Using this data the speed and&#xd;
the acceleration of each one of them were calculated. A descriptive analysis of all kinematic outcomes&#xd;
recorded by the two inertial sensors was developed (trunk and lumbar) and the average range achieved in the&#xd;
FRT. Reliability measures were calculated by analysing the internal consistency the measures with 95%&#xd;
confidence interval of each outcome variable. The reliability was calculated in the functional reach and the&#xd;
outcomes measured by the IS.&#xd;
RESULTS: The values in the the Functional Reach Test obtained in the present study (2.06 ± 12.75cm) are&#xd;
similar to those obtained in other studies with this population and in the same age range. Intrasubject&#xd;
reliability values observed in the use of inertial sensors are all located above 0.820, ranging from 0.829 (time&#xd;
B_C lumbar area) and 0.891 (A_B displacement of the trunk). Likewise, the observed intersubject values&#xd;
range from 0.821 (Time B_C lumbar area) and 0.883 (B_C trunk displacement). On the other hand, the&#xd;
reliability of the FRT was 0.987 (0.983-0.992) and 0.983 (0.979-0.989) intersubject and intrasubject&#xd;
respectively.&#xd;
CONCLUSION: The main conclusion that can be reached is that the inertial sensors are a tool with excellent&#xd;
reliability, validity, sensitivity and specificity in the parameterisation of the Functional Reach Test in people&#xd;
who have had a stroke.</subfield>
   </datafield>
   <datafield ind1="8" ind2=" " tag="024">
      <subfield code="a">http://hdl.handle.net/10630/8268</subfield>
   </datafield>
   <datafield tag="653" ind2=" " ind1=" ">
      <subfield code="a">Electrofisiología</subfield>
   </datafield>
   <datafield ind2="0" ind1="0" tag="245">
      <subfield code="a">Parameterisation and reliability of the functional reach test in people who suffer stroke</subfield>
   </datafield>
</record>
</metadata></record></GetRecord></OAI-PMH>