Mostrar el registro sencillo del ítem
Contributions to displacement and resistance of the meniscus-suture complex in transtibial meniscal root repair
dc.contributor.author | Prado-Novoa, María | |
dc.contributor.author | Pérez-Blanca, Ana | |
dc.contributor.author | Estébanez-Campos, María Belén | |
dc.contributor.author | Nadal-Martínez, Fernando | |
dc.contributor.author | Espejo-Reina, Alejandro | |
dc.contributor.author | Ceccarelli, Marco | |
dc.date.accessioned | 2019-09-18T09:43:54Z | |
dc.date.available | 2019-09-18T09:43:54Z | |
dc.date.created | 2019 | |
dc.date.issued | 2019 | |
dc.identifier.uri | https://hdl.handle.net/10630/18382 | |
dc.description.abstract | This work analyses in a porcine model the contributions of meniscal tissue, suture thread and meniscus-suture interaction to the permanent displacements generated at the repaired root after surgery to re-insert the posterior meniscal root using a transtibial pullout technique. Medial porcine menisci with a single suture applied at the posterior horn were subjected to cyclic and load-to-failure tests. Elongations of the different components of the meniscus-suture complex were determined applying photogrammetry. Results showed that after low intensity cyclic loading, the main contribution to permanent root displacements was due to the thread (51.2%), while no cutting of the suture through tissue occur at the interface. Under load-to-failure conditions, suture cutting started at a significantly higher load level (Suture Retention Strength, SRS), always before and close to the first local maximum of the load-elongation curve, and progressed rapidly afterwards causing the final failure of all specimens | en_US |
dc.description.sponsorship | Universidad de Málaga. Campus de Excelencia Internacional Andalucía Tech | en_US |
dc.language.iso | eng | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Rodillas-Lesiones y heridas-Tratamiento | en_US |
dc.subject | Biomecánica | en_US |
dc.subject.other | Biomechanical properties | en_US |
dc.subject.other | Posterior meniscal root | en_US |
dc.subject.other | Transtibial pull-out repair | en_US |
dc.subject.other | Permanent displacements | en_US |
dc.subject.other | Suture Retention Strength | en_US |
dc.title | Contributions to displacement and resistance of the meniscus-suture complex in transtibial meniscal root repair | en_US |
dc.type | info:eu-repo/semantics/conferenceObject | en_US |
dc.centro | Escuela de Ingenierías Industriales | en_US |
dc.relation.eventtitle | 8th International Conference in Mechanics and Materials in Design | en_US |
dc.relation.eventplace | Bolonia, Italia | en_US |
dc.relation.eventdate | Septiembre, 2019 | en_US |