Mostrar el registro sencillo del ítem

dc.contributor.authorZhao, Piqi
dc.contributor.authorLu, Lingchao
dc.contributor.authorLiu, Xianping
dc.contributor.authorGómez-de-la-Torre, María de los Ángeles 
dc.contributor.authorXin, Cheng
dc.date.accessioned2022-01-13T13:54:38Z
dc.date.available2022-01-13T13:54:38Z
dc.date.issued2018-02
dc.identifier.citationZhao, P.; Lu, L.; Liu, X.; De la Torre, A.G.; Cheng, X. Error Analysis and Correction for Quantitative Phase Analysis Based on Rietveld-Internal Standard Method: Whether the Minor Phases Can Be Ignored? Crystals 2018, 8, 110. https://doi.org/10.3390/cryst8030110es_ES
dc.identifier.urihttps://hdl.handle.net/10630/23611
dc.description.abstractThe Rietveld-internal standard method for Bragg-Brentano reflection geometry (q/2q) X-ray diffraction (XRD) patterns is implemented to determine the amorphous phase content. The effect of some minor phases on quantitative accuracy is assessed. The numerical simulation analysis of errors and the related corrections are discussed. The results reveal that high purity of crystalline phases in the standard must be strictly ensured. The minor amorphous or non-quantified crystalline phases exert significant effect on the quantitative accuracy, even with less than 2 wt% if ignored. The error levels are evaluated by numerical simulation analysis and the corresponding error-accepted zone is suggested. To eliminate such error, a corrected equation is proposed. When the adding standard happens to be present in sample, it should be also carefully dealt with even in low amounts. Based on that ignorance, the absolute and relative error equations (DAE, DRE) are derived, as proposed. The conditions for high quantitative accuracy of original equation is strictly satisfied with a lower amount of standard phase present in sample, less than 2 wt%, and a higher dosage of internal standard, larger than 20 wt%. The corrected equation to eliminate such quantitative error is suggested.es_ES
dc.description.sponsorshipMINECO BIA2014-57658-C2-2-Res_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsinfo:eu-repo/semantics/openAccesses_ES
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectCementoes_ES
dc.subjectEscoriaes_ES
dc.subject.otherRietveldes_ES
dc.subject.otherquantitative phase analysises_ES
dc.subject.otherAmorphouses_ES
dc.subject.otherCementes_ES
dc.subject.otherClinkeres_ES
dc.titleError analysis and correction for quantitative phase analysis based on Rietveld-internal method: Whether the minor phases can be ignored?es_ES
dc.typeinfo:eu-repo/semantics/articlees_ES
dc.centroFacultad de Cienciases_ES
dc.identifier.doihttps://doi.org/10.3390/cryst8030110
dc.rights.ccAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.type.hasVersioninfo:eu-repo/semantics/publishedVersiones_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Excepto si se señala otra cosa, la licencia del ítem se describe como Attribution-NonCommercial-NoDerivatives 4.0 Internacional