    Head-mounted display for clinical evaluation of neck movement validation with Meta Quest 2

    • Autor
      Trinidad-Fernández, Manuel; Bossavit, Benoit; Salgado-Fernández, Javier; Abbate-Chica, Susana; Fernández-Leiva, Antonio JoséAutoridad Universidad de Málaga; Cuesta-Vargas, AntonioAutoridad Universidad de Málaga
    • Fecha
      2023-03-13
    • Editorial/Editor
      MDPI
    • Palabras clave
      Cuello -- Lesiones y heridas -- Diagnóstico; Realidad virtual -- Uso en diagnóstico; Rehabilitacion
    • Resumen
      Neck disorders have a significant impact on people because of their high incidence. The head-mounted display (HMD) systems, such as Meta Quest 2, grant access to immersive virtual reality (iRV) experiences. This study aims to validate the Meta Quest 2 HMD system as an alternative for screening neck movement in healthy people. The device provides data about the position and orientation of the head and, thus, the neck mobility around the three anatomical axes. The authors develop a VR application that solicits participants to perform six neck movements (rotation, flexion, and lateralization on both sides), which allows the collection of corresponding angles. An InertiaCube3 inertial measurement unit (IMU) is also attached to the HMD to compare the criterion to a standard. The mean absolute error (MAE), the percentage of error (%MAE), and the criterion validity and agreement are calculated. The study shows that the average absolute errors do not exceed 1° (average = 0.48 ± 0.09°). The rotational movement’s average %MAE is 1.61 ± 0.82%. The head orientations obtain a correlation between 0.70 and 0.96. The Bland–Altman study reveals good agreement between the HMD and IMU systems. Overall, the study shows that the angles provided by the Meta Quest 2 HMD system are valid to calculate the rotational angles of the neck in each of the three axes. The obtained results demonstrate an acceptable error percentage and a very minimal absolute error when measuring the degrees of neck rotation; therefore, the sensor can be used for screening neck disorders in healthy people
    • URI
      https://hdl.handle.net/10630/26774
    • DOI
      https://dx.doi.org/10.3390/s23063077
    • Compartir
      RefworksMendeley