JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo RIUMAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosDepartamentos/InstitutosEditoresEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosDepartamentos/InstitutosEditores

    Mi cuenta

    AccederRegistro

    Estadísticas

    Ver Estadísticas de uso

    DE INTERÉS

    Datos de investigaciónReglamento de ciencia abierta de la UMAPolítica de RIUMAPolitica de datos de investigación en RIUMAOpen Policy Finder (antes Sherpa-Romeo)Dulcinea
    Preguntas frecuentesManual de usoContacto/Sugerencias
    Ver ítem 
    •   RIUMA Principal
    • Investigación
    • Ponencias, Comunicaciones a congresos y Pósteres
    • Ver ítem
    •   RIUMA Principal
    • Investigación
    • Ponencias, Comunicaciones a congresos y Pósteres
    • Ver ítem

    Simultaneous preconcentration and determination of trace metals (V, Ni, Ti, and Ga) in environmental samples by high resolution continuum source electrothermal atomic absorption spectrometry.

    • Autor
      Vázquez‑Palomo, Laura; Montoro-Leal, Pablo; García-Mesa, Juan Carlos; López-Guerrero, María del MarAutoridad Universidad de Málaga; Vereda-Alonso, Elisa IsabelAutoridad Universidad de Málaga
    • Fecha
      2023
    • Palabras clave
      Nanopartículas; Grafeno; Química analítica
    • Resumen
      In this work is presented a simple, sensitive, low-cost method for direct and simultaneous determination of V, Ti, Ni and Ga by electrothermal atomic absorption spectrometer (ETAAS) in aqueous environmental samples (tap and seawater samples). The system is based on the retention of the analyte on a novel adsorbent material based on the coupling of magnetic nanoparticles (MNPs) and graphene oxide (GO) functionalised with methylthiosalicylate (MTS) that provides selectivity to interact with transition metals in solution, M@GO -MTS. The detection limits achieved with the method were 0.9 μg L-1 for Ti, 0.6 μg L-1 for V, 0.04 μg L-1 for Ga, 0.75 μg L-1 for Ni. The accuracy of the proposed method was demonstrated by analysing two certified reference materials and by determining the analyte content in spiked environmental water samples. The results obtained using this method were in good agreement with the certified values of the standard reference materials and the recoveries for the spiked tap water and seawater samples were between 90% to 120%.
    • URI
      https://hdl.handle.net/10630/28253
    • Compartir
      RefworksMendeley
    Mostrar el registro completo del ítem
    Ficheros
    Abstract.pdf (165.1Kb)
    Colecciones
    • Ponencias, Comunicaciones a congresos y Pósteres

    Estadísticas

    Buscar en Dimension
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
     

     

    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA