Mostrar el registro sencillo del ítem
In vivo assessment of shoulder stability in dynamic rehabilitation exercises: A scoping review
dc.contributor.author | Ramírez-Pérez, Laura | |
dc.contributor.author | Kerr, Graham K. | |
dc.contributor.author | Cuesta-Vargas, Antonio | |
dc.date.accessioned | 2024-12-05T10:08:24Z | |
dc.date.available | 2024-12-05T10:08:24Z | |
dc.date.issued | 2024 | |
dc.identifier.citation | Laura Ramírez-Pérez, Graham K. Kerr, Antonio I. Cuesta-Vargas, In vivo assessment of shoulder stability in dynamic rehabilitation exercises: A scoping review, Gait & Posture, Volume 116, 2025, Pages 30-39, ISSN 0966-6362, https://doi.org/10.1016/j.gaitpost.2024.11.010 | es_ES |
dc.identifier.uri | https://hdl.handle.net/10630/35523 | |
dc.description.abstract | Background: The shoulder complex, which has the highest prevalence of instability, is currently, the subject of considerable debate regarding the methodologies used to assess shoulder stability during dynamic exercises. Research question: The primary aim is to summarize evidence on various methodologies used to evaluate shoulder stability during dynamic exercises. Methods: This scoping review included cross-sectional studies focusing on various evaluation techniques to assess shoulder forces, kinetics, and stability during dynamic movements. In analyzing each study, the selected data included population profile, sample size, exercise type, and evaluation methodology used. Results: Twenty-seven studies with a total of 1187 subjects were included. Among the studies, various dynamic exercises were evaluated, including throwing exercises, movements with dumbbells or elastic bands, push-ups, and functional tasks. Most evaluation techniques were combined, with eleven studies using surface electromy ography; seven used dynamometers to obtain direct strength measurements; two used six-force axis sensors; one utilized force platforms; and one was focused on the loss of speed using linear velocity transducers. Furthermore, motion capture systems such as high-speed cameras were used in fourteen studies. In conclusion, surface elec tromyography and high-speed cameras are the primary techniques for measuring muscle activity and kinetic and kinematic data. However, they do not directly measure glenohumeral stability, meaning further research is needed to develop reliable methodologies for this purpose. Significance: This study holds significant relevance in the field of shoulder instability and has clear clinical im plications, as it establishes the primary tools for estimating glenohumeral stability, which could enable patient stratification and the design of optimal intervention programs based on these measurements. | es_ES |
dc.description.sponsorship | Funding for open access charge: Universidad de Málaga / CBUA This work was supported by the University Teaching Training Programme (FPU) of the Ministry of Universities of Spain. Grant number: FPU21/06296. | es_ES |
dc.language.iso | eng | es_ES |
dc.publisher | Elsevier | es_ES |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Biomecánica | es_ES |
dc.subject | Fisioterapia | es_ES |
dc.subject.other | Assessment | es_ES |
dc.subject.other | Stability | es_ES |
dc.subject.other | Shoulder | es_ES |
dc.subject.other | Biomechanics | es_ES |
dc.subject.other | In vivo | |
dc.title | In vivo assessment of shoulder stability in dynamic rehabilitation exercises: A scoping review | es_ES |
dc.type | journal article | es_ES |
dc.centro | Facultad de Ciencias de la Salud | es_ES |
dc.identifier.doi | 10.1016/j.gaitpost.2024.11.010 | |
dc.type.hasVersion | VoR | es_ES |
dc.departamento | Fisioterapia | |
dc.rights.accessRights | open access | es_ES |