JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo RIUMAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosDepartamentos/InstitutosEditoresEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosDepartamentos/InstitutosEditores

    Mi cuenta

    AccederRegistro

    Estadísticas

    Ver Estadísticas de uso

    DE INTERÉS

    Datos de investigaciónReglamento de ciencia abierta de la UMAPolítica de RIUMAPolitica de datos de investigación en RIUMAOpen Policy Finder (antes Sherpa-Romeo)Dulcinea
    Preguntas frecuentesManual de usoContacto/Sugerencias
    Ver ítem 
    •   RIUMA Principal
    • Investigación
    • Ponencias, Comunicaciones a congresos y Pósteres
    • Ver ítem
    •   RIUMA Principal
    • Investigación
    • Ponencias, Comunicaciones a congresos y Pósteres
    • Ver ítem

    Modelling and dynamic simulation of a liquid desiccant system coupled to a heat pump for air conditioning.

    • Autor
      Prieto, Juan; Atienza-Márquez, Antonio; Coronas, Alberto
    • Fecha
      2019-08-23
    • Palabras clave
      Deshidratantes; Bombas de calor; Optimización matemática
    • Resumen
      In applications where latent loads or ambient humidity are high, liquid desiccant systems combined with vapor compression systems are a suitable alternative to conventional HVAC systems because they can efficiently control air temperature and humidity. In this sense, an optimal integration in terms of working conditions and energy management of both systems is required in order to maximize the overall performance when they are coupled. This study analyses, by means of the modelling and dynamic simulation with TRNSYS, the seasonal performance of a liquid desiccant system coupled to a vapor compression heat pump for an HVAC application. The developed model is then used to optimize to overall performance in terms of energyconsumption and seasonal COP. Different operational conditions and control strategies are evaluated. Results show that evaporator/absorber and condenser/regenerator temperatures are the variables that mainly affect the seasonal COP of the system.
    • URI
      https://hdl.handle.net/10630/37563
    • Compartir
      RefworksMendeley
    Mostrar el registro completo del ítem
    Ficheros
    ICR2019_1102.pdf (2.551Mb)
    Colecciones
    • Ponencias, Comunicaciones a congresos y Pósteres

    Estadísticas

    Buscar en Dimension
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
     

     

    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA