Mostrar el registro sencillo del ítem

dc.contributor.authorAranda-Valera, I. Concepción
dc.contributor.authorCuesta-Vargas, Antonio 
dc.contributor.authorGarrido-Castro, Juan Luis
dc.contributor.authorGardiner, Philip V.
dc.contributor.authorLópez-Medina, Clementina
dc.contributor.authorMachado, Pedro M.
dc.contributor.authorCondell, Joan
dc.contributor.authorConnolly, James
dc.contributor.authorWilliams, Jonathan M
dc.contributor.authorMuñoz-Esquivel, Karla
dc.contributor.authorO'Dwyer, Tom
dc.contributor.authorCastro-Villegas, M. Carmen
dc.contributor.authorGonzález-Navas, Cristina
dc.contributor.authorCollantes-Estévez, Eduardo
dc.date.accessioned2025-02-05T13:48:31Z
dc.date.available2025-02-05T13:48:31Z
dc.date.issued2020-06-24
dc.identifier.citationAranda-Valera IC, Cuesta-Vargas A, Garrido-Castro JL, Gardiner PV, López-Medina C, Machado PM, Condell J, Connolly J, Williams JM, Muñoz-Esquivel K, O'Dwyer T, Castro-Villegas MC, González-Navas C, Collantes-Estévez E, On Behalf Of iMaxSpA Study Group. Measuring Spinal Mobility Using an Inertial Measurement Unit System: A Validation Study in Axial Spondyloarthritis. Diagnostics (Basel). 2020 Jun 24;10(6):426. doi: 10.3390/diagnostics10060426. PMID: 32599741; PMCID: PMC7344521.es_ES
dc.identifier.urihttps://hdl.handle.net/10630/37716
dc.description.abstractPortable inertial measurement units (IMUs) are beginning to be used in human motion analysis. These devices can be useful for the evaluation of spinal mobility in individuals with axial spondyloarthritis (axSpA). The objectives of this study were to assess (a) concurrent criterion validity in individuals with axSpA by comparing spinal mobility measured by an IMU sensor-based system vs. optical motion capture as the reference standard; (b) discriminant validity comparing mobility with healthy volunteers; (c) construct validity by comparing mobility results with relevant outcome measures. A total of 70 participants with axSpA and 20 healthy controls were included. Individuals with axSpA completed function and activity questionnaires, and their mobility was measured using conventional metrology for axSpA, an optical motion capture system, and an IMU sensor-based system. The UCOASMI, a metrology index based on measures obtained by motion capture, and the IUCOASMI, the same index using IMU measures, were also calculated. Descriptive and inferential analyses were conducted to show the relationships between outcome measures. There was excellent agreement (ICC > 0.90) between both systems and a significant correlation between the IUCOASMI and conventional metrology (r = 0.91), activity (r = 0.40), function (r = 0.62), quality of life (r = 0.55) and structural change (r = 0.76). This study demonstrates the validity of an IMU system to evaluate spinal mobility in axSpA. These systems are more feasible than optical motion capture systems, and they could be useful in clinical practice.es_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.subjectArticulaciones - Enfermedadeses_ES
dc.subjectReumatologíaes_ES
dc.subject.otherAxial spondyloarthritises_ES
dc.subject.otherInertial measurement unites_ES
dc.subject.otherSpinal mobilityes_ES
dc.titleMeasuring Spinal Mobility Using an Inertial Measurement Unit System: A Validation Study in Axial Spondyloarthritis.es_ES
dc.typejournal articlees_ES
dc.identifier.doi10.3390/diagnostics10060426
dc.type.hasVersionVoRes_ES
dc.departamentoFisioterapia
dc.rights.accessRightsopen accesses_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem