JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo RIUMAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentros

    Mi cuenta

    AccederRegistro

    Estadísticas

    Ver Estadísticas de uso

    DE INTERÉS

    Datos de investigaciónReglamento de ciencia abierta de la UMAPolítica de RIUMAPolitica de datos de investigación en RIUMASHERPA/RoMEODulcinea
    Preguntas frecuentesManual de usoDerechos de autorContacto/Sugerencias
    Ver ítem 
    •   RIUMA Principal
    • Investigación
    • Química Analítica - (QA)
    • QA - Contribuciones a congresos científicos
    • Ver ítem
    •   RIUMA Principal
    • Investigación
    • Química Analítica - (QA)
    • QA - Contribuciones a congresos científicos
    • Ver ítem

    Synthesis of a new functionalized mesoporous silica for determination of antimony by flow injection solid phase extracton coupled with on line hydride generation ETAAS.

    • Autor
      López-Guerrero, María del MarAutoridad Universidad de Málaga; Siles-Cordero, Maria TeresaAutoridad Universidad de Málaga; García-de-Torres, AmparoAutoridad Universidad de Málaga; Cano-Pavón, José ManuelAutoridad Universidad de Málaga; Vereda-Alonso, Elisa IsabelAutoridad Universidad de Málaga
    • Fecha
      2013-12-19
    • Palabras clave
      Antimonio
    • Resumen
      A chelating resin, [1,5 bis(di-2-pyridyl) methylene thiocarbohydrazide] bonded to mesoporous silica (DPTH-ms), has been used as a novel solid phase extractant. This resin has some advantages compared to most of other chelating adsorbents. Therefore, the aim is to develop a reliable method for determination of the aforementioned element from natural water samples by the on-line column preconcentration/HG-ETAAS using the resin DPTH-ms. With all experimental variables optimized, a linear calibration graph was obtained from 0.01 µg l-1 to 2.5 µg l-1of Sb(III) with a regression coefficient of 0.9952, Table 1. Table 1. Analytical performance. Calibration equationa (n=6) Blank signal/mV Detection limit / µg L-1 Determination limit / µg L-1 Enrichment factor Y=0.205x+0.049 0.044±0.018 0.002 0.065 5.00 a y, signal/mV; x, concentration/ µg L-1 In order to test the accuracy and applicability of the proposed method for the analysis of real natural water samples and several certified reference materials of environmental waters, were analyzed. These samples were employed for the validation of the method. These results show good agreement with the certified values, according to the t-test for a confidence level of 95% and they show sufficiently high recoveries. Because these standard reference samples have included trace elements such as transition metals, it can be said that there is no interference from these metals at ng ml-1 concentrations.
    • URI
      http://hdl.handle.net/10630/6822
    • Compartir
      RefworksMendeley
    Mostrar el registro completo del ítem
    Ficheros
    Congreso Santander-2-1.pdf (97.20Kb)
    Colecciones
    • QA - Contribuciones a congresos científicos

    Estadísticas

    Ver Estadísticas de uso
    Buscar en Dimension
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
     

     

    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA