JavaScript is disabled for your browser. Some features of this site may not work without it.

    Listar

    Todo RIUMAComunidades & ColeccionesPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentrosEsta colecciónPor fecha de publicaciónAutoresTítulosMateriasTipo de publicaciónCentros

    Mi cuenta

    AccederRegistro

    Estadísticas

    Ver Estadísticas de uso

    DE INTERÉS

    Datos de investigaciónReglamento de ciencia abierta de la UMAPolítica de RIUMAPolitica de datos de investigación en RIUMASHERPA/RoMEODulcinea
    Preguntas frecuentesManual de usoDerechos de autorContacto/Sugerencias
    Ver ítem 
    •   RIUMA Principal
    • Investigación
    • Fisioterapia - (PF)
    • PF - Contribuciones a congresos científicos
    • Ver ítem
    •   RIUMA Principal
    • Investigación
    • Fisioterapia - (PF)
    • PF - Contribuciones a congresos científicos
    • Ver ítem

    Parameterisation and reliability of the functional reach test in people who suffer stroke

    • Autor
      Merchan Baeza, Jose Antonio; Gonzalez-Sanchez, ManuelAutoridad Universidad de Málaga; Cuesta-Vargas, AntonioAutoridad Universidad de Málaga
    • Fecha
      2014-10-22
    • Palabras clave
      Electrofisiología
    • Resumen
      AIM: The aim of this study is to analyse the reliability, sensitivity and specificity of the parameterisation of FRT using inertial sensors to record kinematic variables in subjects who have had a stroke. Our hypothesis is that the IS will be reliable instruments for kinematic study of the FRT. METHODS: This is a cross-sectional study of 5 subjects over 65 years who suffer of stroke. During the execution of Funtional Reach Test the subjects carried two inertial sensors, one was placed in the lumbar and the other in the trunk. After analysing the data obtained in the kinematic registration by inertial sensors a number of direct and indirect variables were obtained. The variables extracted directly from FRT through the IS were distance, maximun angular lumbosacral/thoracic displacement, time maximun angular lumbosacral/thoracic displacement, time return starting position and total time. Using this data the speed and the acceleration of each one of them were calculated. A descriptive analysis of all kinematic outcomes recorded by the two inertial sensors was developed (trunk and lumbar) and the average range achieved in the FRT. Reliability measures were calculated by analysing the internal consistency the measures with 95% confidence interval of each outcome variable. The reliability was calculated in the functional reach and the outcomes measured by the IS. RESULTS: The values in the the Functional Reach Test obtained in the present study (2.06 ± 12.75cm) are similar to those obtained in other studies with this population and in the same age range. Intrasubject reliability values observed in the use of inertial sensors are all located above 0.820, ranging from 0.829 (time B_C lumbar area) and 0.891 (A_B displacement of the trunk). Likewise, the observed intersubject values range from 0.821 (Time B_C lumbar area) and 0.883 (B_C trunk displacement). On the other hand, the reliability of the FRT was 0.987 (0.983-0.992) and 0.983 (0.979-0.989) intersubject and intrasubject respectively. CONCLUSION: The main conclusion that can be reached is that the inertial sensors are a tool with excellent reliability, validity, sensitivity and specificity in the parameterisation of the Functional Reach Test in people who have had a stroke.
    • URI
      http://hdl.handle.net/10630/8268
    • Compartir
      RefworksMendeley
    Mostrar el registro completo del ítem
    Ficheros
    PARAMETERISATION AND RELIABILITY.pdf (135.8Kb)
    Colecciones
    • PF - Contribuciones a congresos científicos

    Estadísticas

    Ver Estadísticas de uso
    Buscar en Dimension
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
     

     

    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA
    REPOSITORIO INSTITUCIONAL UNIVERSIDAD DE MÁLAGA